3-Way, Balanced Valves /
The VC series 2-position hydronic valves are used in domestic and small
commercial applications to control the flow of hot and/or cold water or glycol
solution up to 50% concentration. They consist of an actuator, valve and a
replaceable cartrige assembly.
These 3-Way valves are designed for ON-OFF control and can be piped for
either diverting or mixing valve applications for domestic hot water service, in
central heating and/or cooling systems; or for individual room temperature
control (fan coil, radiator or convector applications).
Depending on the model selected, they can be controlled by either a low or line
voltage SPST
or SPDT
thermostat, a chronotherm or other suitable two-position controller.
Le valvole a 2 posizioni Serie VC trovano impiego in ambito domestico ed in
piccoli edifici ad uso commerciale per il controllo della portata dell'acqua calda
e/o fredda o in soluzione con glicole, in concentrazione fino al 50%. Sono
costituite da un attuatore e dal corpo valvola, quest'ultimo dotato di otturatore,
con guida a lanterna sostituibile.
Las válvulas de 2 posiciones Serie VC se usa en aplicaciones domésticas y
pequeños edificios para controlar el caudal de agua caliente y/o fría o de una
solución de glicol de hasta el 50% de concentración. Constan de un actuador,
válvula y un cartucho que se puede sustituir.
Estas válvulas de 3 vías están diseñadas para control ON-OFF y se pueden
montar en línea para aplicaciones de desvío o mezcla en el servicio de agua
The following specifícations are nominal and conform to generallly accepted
industry standards. Honeywell is not responsibie for damages resulting from
misapplication or misuse of its products.
Voltage :
230V 50-60Hz, standard models. 24V 50-60Hz models are available on
request.
Power Consumption:
6 Watts Max. at nominal Voltage (during valve position change).
Maximum duty Cycle : 15 %
End switch rating :
2.2 A inductive from 5 to 110 Vac,
1.0 A inductive above 110 to 277 Vac.
Min. DC switching capability: 5 mA @ 24 Vdc
Nominal timing :
Valve opens in 6 seconds @ 60 Hz (20% longer @ 50 Hz)
Electrical termination :
With integral 1 meter leadwire cable, standard models.
Models with Molex™ connector are available on request.
I Dati Tecnici riportati di seguito sono nominali e conformi agli standard
accettati nell'industria. Honeywell non è responsabile per danni risultanti da
applicazioni improprie o uso errato dei propri prodotti.
Alimentazione :
230V 50-60Hz, modelli standard. 24V 50-60Hz, disponibile su richiesta.
Assorbimento:
6 Watt Massimo. a tensione nominale (durante il movimento del motore).
Duty Cycle : 15 % massimo
Portata del contatto ausiliario :
2,2 A induttivi da 5 a 110 V ca,
1,0 A induttivi oltre 110 e fino a 277 V ca.
Corrente continua: minima 5 mA @ 24 V cc
Tempo di escursione nominale :
La valvola apre in 7,2 secondi @ 50 Hz (6 secondi @ 60 Hz)
2003.02.24
© Honeywell Limited.
Valvole a 3 vie Bilanciate
APPLICATION
controller contact, such as a room
APPLICAZIONE
APLICACIÓN
SPECIFICATIONS
DATI TECNICI
/
Válvulas de 3 vías, equilibradas
Le valvole VC a 3 vie trovano impiego per il controllo ON-OFFe possono essere
montate sia come miscelatrici che come deviatrici per la precedenza dell'acqua
calda sanitaria nel riscaldamento/raffreddamento domestico autonomo
individuale o a zone ed in piccoli sistemi di condizionamento dell'aria.
In base al modello selezionato, possono essere comandate da un termostato,
un cronotermostato o altro regolatore appropriato, con contatto, a tensione di
linea o a bassa tensione, di tipo SPST
caliente sanitaria, en calefacción central o en sistemas de refrigeración; también
para control individual de temperatura de habitaciones (fan-coil, radiadores o
convectores).
Dependiendo del modelo seleccionado, se pueden controlar mediante un
interruptor unipolar SPST
o un inversor SPDT
línea, como un termostato de ambiente, un Chronotherm u otro controlador
adecuado de dos posiciones.
Operating ambient temperature :
0 to 65°C
Shipping & storage temperature :
-40 to +65°C
Atmosphere: non-corrosive, non-explosive
Min. & max. fluid temperatures : 1 to 95°C
Operating pressure differential : Max. - 4 bar (400 kPa)
Pressure rating : Static - 20 bar (2000 kPa)
Valve materials: Body of bronze; cartridge of Ryton™ (polyphenylene
sulphide) & Noryl™ (polyphenylene oxide); O-ring seals of EPDM rubber;
stainless steel stem.
Dimensions / pipe fitting sizes / flow ratings (nominal Kv) :
See Table 1.
Insulation class : Double insulation
Protection class : IP40
Approval : CE
Collegamenti elettrici :
Versioni standard, con cavo da 1 metro in dotazione precablato.
Versioni con connettore Molex™ disponibili su richiesta.
Temperatura ambiente di funzionamento :
0 ... 65°C
Temperatura di stoccaggio e trasporto :
-40 ... +65°C
Atmsfera operativa: non-corrosiva, non-esplosiva
Temperature min. & max. dell'acqua: da 1 a 95°C
Pressione differenziale di funzionamento : 4 bar massimo (400 kPa)
Pressione statica nominale : 20 bar (2000 kPa)
Materiali della valvola: Corpo in bronzo; Otturatore in Ryton™ (polyphenylene
sulphide) & Noryl™ (polyphenylene oxide); O-ring di tenuta in gomma EPDM;
stelo in acciaio inox.
Dimensioni / tipi di attacchi / Kv nominali : Ved. Tab. 1.
Clsse di isolamento : Doppio isolamento
Classe di approvazione meccanica : IP40
VC SERIES
oppure SPDT
.
de voltaje bajo o de
Form No. 95C-10647-4
Home & Building Control Group

Publicidad

loading

Resumen de contenidos para Honeywell VC Serie

  • Página 1 0 to 65°C The following specifícations are nominal and conform to generallly accepted Shipping & storage temperature : industry standards. Honeywell is not responsibie for damages resulting from -40 to +65°C misapplication or misuse of its products. Atmosphere: non-corrosive, non-explosive Voltage : Min.
  • Página 2: Especificaciones

    Las siguientes especificaciones son nominales y se ajustan a estándares 0 a 65°C normalmente aceptados en la industria. Honeywell no se hace responsable de Temperatura de transporte y almacenamiento: los daños que resulten de la aplicación o uso incorrecto de sus productos.
  • Página 3: Instalación

    *) Other types available on request / (*) Altri modelli disponibili su richiesta / (*) Otros tipos disponibles bajo demanda MANUAL OPENER The manual opener (Fig. 6) can be manipulated only when in the up position. failure.The valve can be restored manually to the closed position (stem up) by This must be done without electrical hook-up.
  • Página 4 torque limit is 45 N.m for the 22 mm compression fitting, and 65 N.m for the PLUMBING 28 mm compression fitting. While not necessary to remove the actuator from the body, it can be Either hold valve body in your hand (Fig. 5-A) or attach adjustable spanner removed for ease of installation.
  • Página 5: Collegamenti Elettrici

    Fig. 3 – Valve mounting position Fig. 4 – Removing the actuator Fig. 5 - Valve mounting Fig. 6 – The manual opener Posizione della valvola Rimozione dell’attuatore Montaggio della valvola Leva di apertura manuale Posición de montaje Retirada del actuador Montaje de la válvula Accionador de apertura manual WIRING...
  • Página 6 TABLA A – TERMINACIÓN ELÉCTRICA ‘COLORES Y NÚMEROS DE PIN’ TABLA B – TERMINACIÓN ELÉCTRICA - 'FUNCIÓN DE LOS CONTACTOS’ TIPO DE VÁLVULAS MODELOS DE MODELOS MODELOS DE CABLE MODELOS MOLEX™ ACTUADOR DE 3 VÍAS CABLE MOLEX™ TERMINAL ACCIÓN Azul y marrón Vástago arriba Color de cable Pin #2 y 3 energizado...
  • Página 7 NOTA: dispositivos de control La válvula se debe abrir y el interruptor Las válvulas Honeywell para agua han sido diseñadas y testadas para que auxiliar (si existe) se debe cerrar haciendo contacto al final del funcionen silenciosamente en sistemas diseñados e instalados adecuadamente.
  • Página 8 Honeywell Automation and Control Solutions In Canada: Printed in Canada Environmental Control Products Honeywell Limited-Limitee 1985 douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422-3992 Toronto, ON M1V 4Z9 Form No. 95C-10647-4 U.S.A. Canada...

Este manual también es adecuado para:

Vc6613me6000Vc6613mh6000Vc6613mg6000Vc6613mp6000Vc6613mq6000