Cleaning
For cleaning purposes, the fitting can be switched off by
attaching the enclosed cleaning clip (M), see Fig. [9].
Maintenance
Shut off the hot and cold water supplies and switch off the
voltage supply.
Inspect, clean and, if necessary, replace parts.
I. Transformer
1. Interrupt the voltage supply via transformer (E), see Fig. [10].
2. Detach plug-in connector (D).
Assemble in reverse order.
II. Solenoid valve (12 V DC)
1. Remove screw (N) and detach housing (O), see Fig. [11].
2. Remove screws (P1) and detach retaining plate (P).
3. Detach plug-in connection (Q) and remove solenoid
valve (R) by turning clockwise using a 5mm allen key,
see Fig. [12].
4. Remove filter (T).
Install in the reverse order observing the installation position.
III. filter, see Fig.13
Assemble in reverse order.
IV. Remove and clean mousseur (13 943)
Assemble in reverse order.
V. Mixer spindle
1. Disconnect fitting from connections.
2. Remove fitting from wash basin. Disassembly is as
described in section "Setting temperature limiter",
see Figs. [7] to [8].
3. Remove screw (U) from housing using a 2.5mm allen key,
see Fig. [14].
4. Pull out mixer spindle (H, L).
Assemble in reverse order.
Fault/ Cause/ Remedy
Fault
Cause
Water not flowing
• Water supply interrupted
• Filter upstream of solenoid valve blocked
• Solenoid valve defective
• Plug-in connector of solenoid valve
without contact
• No voltage
• Hands not in reception range
Water flowing
• Solenoid valve defective
continuously
Undesired water flow
• Sensor system detection zone set too
high for local conditions
Flow rate too low
• Filter or mousseur dirty
• Service valves not fully open
• Water supply restricted
Incorrect mixed
• See "Flow rate too low"
temperature
• Limescale on mixer spindle
• Temperature limiter incorrectly set
Screw (U) must engage in groove (H1, L1) of mixer
spindle (H, L).
Replacement parts, see fold-out page I (* = special
accessories).
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Remedy
- Open shut-off valves, service valves
- Clean, see Maintenance, Solenoid valve
- Replace, see Maintenance, Solenoid valve
- Attach plug-in connector
- Switch on power supply, check plug-in connectors
- Hold hands directly under the spout
- Replace, see Maintenance, Solenoid valve
- Reduce range using remote control (special
accessory, Prod. no.: 36 407)
- Replace, see Maintenance, Filter and Mousseur
- Fully open shut-off valves, service valves
- Check supply lines, open service valves
- Clean, see Maintenance, Mixer spindle
- Adjust, see description
4