5. Layout and items supplied (Fig. 1-3)
1. Fuel tank
2. Tank cover
3. Inverter cover
4. Starter cable
5. Petrol cock
6. Choke lever
7. ON/OFF switch
8. Earthing connection
9. Economy switch
10. 2x 230 V~ socket
11. Hour meter
12. DC Output
13. Overload indicator
14. Operating status indicator
15. Oil warning indicator
16. Screwdriver handle
17. Screwdriver insert
18. Spark plug wrench
19. Oil drainage pipe (inside of jug)
20. Oil filler jug
21. Accessories bag
22. Socket wrench insert
23. 8 and 10 mm wrench
24. Frame
6. Technical data
Engine
Model:
Protection type:
Engine:
4-stroke engine.OHV,1 cylinder
Cubic capacity:
Degree of compression:
Nominal speed:
(SMART throttle switch in "OFF" position)
Cooling system:
Oil tank volume:
Fuel tank volume:
Spark plug:
Generator
Mains voltage (V):
Frequency (Hz):
Ampere (A):
Nominal power PRP (kW):
Power factor:
Power class:
Noise:
Application information:
1. Optimum temperature in operation: 5 - 40 °C.
2. Altitude:maximum 1000 m.
3. Optimum temperature for storage of the generator:
- 25 - 70 °C.
7. Before putting the generator into
operation
Remove the packaging material and check that all
items have been supplied. Place the generator on a
firm, flat surface near the electrical equipment and
ensure proper ventilation.
7.1 Electrical safety:
Electric supply cables and connected equipment must
•
be in perfect condition.
The generator is to be operated only with equipment
•
whose voltage specifications conform with the
generator's output voltage.
Never connect the generator to the power supply
•
(socket-outlet).
CP168FB
IP 23M
Keep the cable length to the electrical equipment as
•
short as possible.
196 cc (68x54 mm)
8,5:1
7.2 Environmental protection
-1
3200 min
Dispose of soiled maintenance material and operating
•
Fan cooling
materials at the appropriate collection point.
0,6 L
14 L
Recycle packaging material, metal and plastics.
•
F6RTC
7.3 Connecting to earth (Fig.2)
230 V
The housing is allowed to be connected to earth in
12 V d.c 8.3 A
order to discharge static electricity. To do this, connect
50 Hz
one end of a cable to the earth connection on the
8,7 A
generator (Item 8) and the other end to an external earth
9
G
B
2,0
1,0
G2
95 dB(A)