Air Filter; Spark Plug; Technical Data - Stanley SIG 2000 Silent Traducción Del Manual Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 78
G
B

6.4 Air filter

Clean the air filter at regular intervals and replace it, if
required. Please also observe the service information.
Remove the engine cover (fig. 6a-6b/pos. 5)
Remove the air filter lid (fig. 11, pos. 25)
Remove the filter element (fig. 11/pos. 24)
Clean the filter element by tapping it. In the event of
hard-to-remove dirt, wash it with soapy water, then
rinse it with clean water and let it dry outside before re-
installing it. Caution! Do not use aggressive detergents
or petrol for cleaning the filter elements.
Re-assembling is performed in reverse order.

6.5 Spark plug

Check the spark plug at regular intervals for dirt. please
also observe the service information.
Remove the spark plug lid (fig. 12a-12b/pos. 6).
Pull off the spark plug socket (fig. 12c/pos. 23) by
turning it.
Remove the spark plug (fig. 12c/pos. 22) by means of
the supplied spark plug socket. (fig. 3/pos. 23).
Clean the spark plug by means of a copper wire brush or
insert a new plug.
Re-assembling is performed in reverse order.
6.6 Storage
1. Empty the petrol tank by means of a petrol suction
pump.
Caution! Do not remove the petrol in closed rooms, in
close proximity to fire or when smoking. Gas fumes may
cause explosions or fire.
2. Start the engine and let the engine run until the
remaining petrol is consumed.
3. Let the device cool down.
4. Remove the spark plug and fill in approximately 20 ml
of engine oil into the cylinder.
5. Pull the starter handle slowly several times in order to
wet the internal components with oil.
6. Screw in the spark plug.
7. Store the device in a well-ventilated, secure place.
6.7 Transport
1. Wait until the device has cooled down.
2. Turn the tank lid ventilation (fig. 4/pos. 7) to "OFF" (fig.
4/pos. B).
Caution! The device may only be transported in an
upright position even if the tank ventilation is closed.

7. Technical data

Generator:
Protection class:
Continuous output PRP (230 V):
Maximum output Pmax (230 V):
Nominal voltage Urated:
Nominal current Irated:
Frequency Frated:
Drive engine design:
Engine displacement:
Max. output (engine):
Fuel:
Tank capacity:
Engine oil:
Consumption at 2/3 load:
Weight:
Sound pressure level L
pA
Sound power level L
:
WA
Power factor cos φ:
Power performance / class:
Guaranteed sound power level L
Temperature max:
Max. installation altitude (above sea level):
12
Digital inverter
IP23M
1600 W
2000 W
1 x 230 V~ / 1 x 12 VDC
7 A (230 V) / 8.3 A (12 V)
50 Hz
4-stroke air-cooled ventilation
80 cm³
2.5 kW / 3.4 PS
Unleaded petrol
approx. 0.35 l
approx. 0.7 l/h
21 kg
:
66 dB(A)
86 dB(A)
G2/A
:
88 dB(A)
WA
40 °C(104° F)
1000 m
4.0 l
1

Publicidad

Tabla de contenido
loading

Tabla de contenido