TECHNICAL DATA
MODEL
TYP
OUTPUT
(1)
FUEL
- Net calorific value
- Absolute density
- Max delivery
- Pressure at maximum delivery
OPERATION
STANDARD APPLICATION
AMBIENT TEMPERATURE
COMBUSTION AIR TEMPERATURE
ELECTRICAL SUPPLY
ELECTRICAL MOTOR
MOTOR CAPACITOR
IGNITION TRASFORMER
ELECTRICAL POWER CONSUMPTION
ELECTRICAL PROTECTION
IN CONFORMITY WITH EEC DIRECTIVES
NOISE LEVELS
(3)
APPROVAL
(1) Reference conditions: Ambient temperature 20°C - Barometric pressure 1000 mbar - Altitude 100 m a.s.l.
(2) Pressure at test point 8)(A)p.3, with zero pressure in the combustion chambre, with open gas ring 2)(B)p.7 an maximum burner output
(3) Sound pressure measured in manufacturer's combustion laboratory, with burner operating on test boiler and at maximum rated output.
VARIANTS
Electrical
Model
supply
single-phase
RS 28
single-phase
single-phase
single-phase
RS 38
three-phase
three-phase
three-phase
RS 50
three-phase
ACCESSORIES (optional):
•
KIT FOR LPG OPERATION: The kit allows the RS 28-38-50 burners to operate on LPG.
BURNER
OUTPUT
BLAST TUBE LENGTH
CODE
•
VIBRATION REDUCTION KIT
BURNER
CODE
•
GROUND FAULT INTERRUPTER: code 3010321
•
STATUS (see page 20): code 3010322
•
GAS TRAIN ACCORDING TO REGULATION EN 676 (with valves, pressure governor and filter): see page 8.
Important:
The installer is responsible for the addition of any safety device not forseen in the present manual.
2nd stage
min. 1st stage
(2)
Blast tube
length mm
216
351
216
351
216
351
216
351
RS 28
kW
95 ÷ 325
mm
216
3010079
3010080
RS 28
3010198
RS 28
809 T1
kW
163 - 325
Mcal/h
140 - 280
kW
81
Mcal/h
70
NATURAL GAS: G20 - G21 - G22 - G23 - G25
G20
G25
3
10
8,6
kWh/Nm
8,6
7,4
3
Mcal/Nm
0,71
0,78
3
kg/Nm
3
32
38
Nm
/h
mbar
7,5
11,1
• Intermittent (min. 1 stop in 24 hours)
• Two-stage (high and low flame) and single-stage (all - nothing)
Boilers: water, steam, diethermic oil
°C
0 - 40
°C max
60
V
230 ~ +/-10%
Hz
50 - single-phase
rpm
2800
W
250
V
220 - 240
A
2,1
µF/V
8/450
V1 - V2
230 V - 1 x 8
I1 - I2
kV
1 A - 20 mA
W max
370
IP 44
90/396 - 89/336 - 73/23 - 92/42
dBA
68
CE
0085AP0733
GAS CATEGORY
IT - AT - GR - DK - FI - SE
RS 38
115 ÷ 440
351
216
3010081
RS 38
3010199
2
RS 38
RS 38
810 T1
810 T1
232 - 440
232 - 440
200 - 378
200 - 378
105
105
90
90
G20
G25
G20
G25
10
8,6
10
8,6
8,6
7,4
8,6
7,4
0,71
0,78
0,71
0,78
44
51
44
6,6
9,7
6,6
9,7
230 - 400 with neutral ~ +/-10%
50 - three-phase
2800
2800
420
450
220 - 240
220/240-380/415
2,9
2 - 1,2
12,5/450
600
560
70
70
0085AP0734
0085AP0734
COUNTRY
ES - GB - IE - PT
NL
FR
DE
BE
LU
140 ÷ 581
351
216
3010082
3010083
RS 50
811 T1
290 - 581
249 - 500
116
100
G20
G25
10
8,6
8,6
7,4
0,71
0,78
51
58
68
7,2
10,6
2800
650
220/240-380/415
3 - 1,7
750
72
0085AP0735
CATEGORY
II
2H3B / P
II
2H3P
II
2L3B / P
II
2Er3P
II
2ELL3B /P
I
I
2E(R)B,
3P
II
2E 3B/P
RS 50
351
3010084
RS 50
3010200