English
SPECIFICATIONS
Model
Motor
Power Source
Output Power
Current
Tank Capacity
Maximum Pressure
at 40 PSI
(2.8 bar)
Free Air
at 90 PSI
Delivery
(6.2 bar)
at 100 PSI
(6.9 bar)
Lubrication
ACCESSORY
WARNING:
Accessory other than these shown
below can lead to malfunction and
resulting injuries.
STANDARD ACCESSORY
APPLICATIONS
Air source of the pneumatic nailer and stapler.
WARNING:
Never use compressor for
applications other than compressor
for pneumatic nailer and stapler.
Dipstick - - - - - - - - - - - - - - 1
EC119
Single-Phase, Induction Motor
Single-Phase, 120V AC 60Hz
2 HP
(1.5 KW)
15.0 A
4 gal.
(15.1 ltr)
125 PSI
(8.6 bar)
5.3 CFM
(150 ltr/min)
4.4 CFM
(125 ltr/min)
4.0 CFM
(113 ltr/min)
Oil
PRIOR TO OPERATION
1. Power source
Ensure that the power source to be utilized conforms
to the power source requirements specified on the
product nameplate.
2. Power switch
Ensure that the knob of the pressure switch is in the
"OFF" position (Fig. 2). If the plug is connected to a
receptacle while the knob is in the "ON" position, the
compressor will start operating immediately and can
cause serious injury.
3. Extension cord
When the work area is far away from the power
source, use an extension cord of sufficient thickness
and rated capacity (refer page 7). The extension cord
should be kept as short as practicable.
WARNING:
Damaged cord must be replaced or
repaired.
— 10 —
Knob of the pressure switch
Fig. 2