System with CCTV interface Ref. 1783/69
ADVANCED CONFIGURATION
In two-family systems with double call station, one station can be associated with user 0 and the other with
user 1:
•
Confi gure the two call stations as "single-family" (AUX dip 6 = OFF).
•
Confi gure the call station associated with user 0 as main (AUX dip 1 = OFF) and ID = 0.
•
Confi gure the call station associated with user 1 as secondary (AUX dip 1 = ON) with address 1 (AUX dip
2 = ON) and ID = 0.
•
Position the rotary switch (CONV TIME) of the call station associated with user 1 to position "9". The
station emits a confi rmation tone.
•
On the call station associated with user 1, set the number of the door speaker unit ID = 1.
•
Change the position of AUX dip-switch no. 5 (the call module emits a confi rmation tone).
•
Set again the AUX dip-switch no. 5 in its previous position (the call module emits a confi rmation tone).
•
Set again the ID dip-switches in their previous position (ID = 0).
•
Exit from advanced confi guration, returning the rotary witch to the position for setting guaranteed
conversation time.
Example:
The main call station "A" calls only user 0 with both keys while the secondary call station "B" calls only user
1 with both keys.
•
On the call module "B" access to advanced confi guration;
•
Set the ID dip-switch to 1;
•
Move the AUX dip-switch no. 5;
•
Set again all the dip-switches in their previous position;
•
Exit from the advanced confi guration.
16
TVCC
interface
Ref. 1783/69
LINE 1
2Voice
power supply
LINE 2
Calling station
ID = 0
Aux dip 1 = OFF (main)
DS1783-002C