Technical specifications
Parameter
Units
Voltage
V
Power rating
kW
Protection
IP
Insulation
Class
Protection (electrical)
Class
Noise level
dB(A)
Container capacity
L
Inlet (diameter)
mm
Max vacuum
mbar
Maximum air flow rate
(without hose and
L/min'
reductions)
Main filter surface
m
2
Dimensions
Figure 3
Model
L 50
1250
A (mm)
L 100
-
GU
-
B (mm)
980
C (mm)
600
kg
100
(1)
(1) Net weight
[ NOTE ]
■
Storage conditions:
Temperature: -10°C ÷ +40°C
Humidity: ≤ 85%
■
Operating conditions:
Maximum altitude: 800 m
(Up to 2,000 m with reduced performances)
Temperature: -10°C ÷ +40°C
Humidity: ≤ 85%
01/2015
T30S (50 Hz)
T30S (60 Hz)
400
220/380/440
3
3,6
55
55
F
F
GB
GB
70
73
50 / 100
50 / 100
70
70
310
380
5830
6830
1,95
1,95
T30S
-
-
1530
-
-
1530
980
980
600
600
103
103
Controls, indicators and connections
1
Dust container release lever
2
Wheel brake
3
Manual filter shaker knob
4
Start/stop switch
Inspection prior to starting
1
Inlet
Prior to starting, check that:
■
The filter is installed.
■
All latches are tightly locked;
■
The vacuum hose and tools have been correctly fitted
into the inlet (1)
Do not use the vacuum cleaner if the filter is faulty.
Starting up
1
Castor brakes
2
Start/stop switch
Lock the castor brakes before starting the vacuum cleaner (1).
Starting/stopping the vacuum cleaner
Normal version
■
Press or turn the switch (2) to "I" position to start the
vacuum cleaner.
■
Press or turn the switch to "0" position to turn the vacuum
cleaner off.
Checking the rotation direction of the vacuum unit motor
Check the vacuum cleaner operation by putting a hand on the
inlet.
If the vacuum cleaner expels the air from the vacuum hose,
the rotation direction is not correct; remove the plug from the
socket and ask for assistance from qualified personnel to
perform the correct phase connection.
7
Figure 4
Figure 5
Figure 6
T30S
GB
C341