EN
flows back into the tank through the high
pressure filter, the high pressure ball
valve and the return pipe.
6. Remove the spray tip from the gun and
point the gun into the tank. Unlock the
safety lever on the gun. Operate the
gun trigger and close the high pressure
ball valve. The spray material will now
flow through the high pressure filter,
the fluid hose and the gun, back into
the tank.
7. Release the gun trigger and set the
working pressure at the regulator.
NOTE
Before carrying out any coating work, we
recommend a test spray (e.g. on to paper
or wood). Only if the test gives you the
desired result should you start to coat the
actual object.
WORK STOPPAGES
CAUTION
!
If working with 2-K spray material, you
must note the given pot life and follow
it precisely. Within this time, the unit
must be carefully cleaned and rinsed
with the recommended solvent. There
must be no residue left in the pump,
the high pressure filter or the gun.
CAUTION
!
When work is stopped, the safety lever
of the gun must be locked.
For work stoppages of between 10 and
30 minutes, please proceed as follows:
WARNING
!
Wear eye protection.
1. Lock the safety lever on the gun.
2. Shut off the compressed air supply by
closing the ball valve.
3. Briefly open the high pressure ball
valve, taking care that the return flow
hose is not pointed at other people
or at yourself, until the pressure has
reduced. Then close the high pressure
ball valve again.
4. Clean the outside of the spray nozzle
from spray material residue.
STARTUP AND OPERATION
SHUT-DOWN
CAUTION
!
Once work is completed, the BINKS
pump must be thoroughly cleaned.
Under no circumstances must you
allow paint residue to dry out in the
unit. To clean the pump, use a solvent
appropriate to the spray material.
WARNING
!
Wear eye protection.
1. Close the ball valve for the compressed
air supply.
2. Make sure that the flow hose is still
directed into the spray material tank.
Carefully open the high pressure ball
valve to reduce the pressure in the
pump and in the high pressure filter.
3. Remove the spray tip from the gun.
4. Point the gun into the tank of spray
material and operate the trigger to
reduce any pressure which may still
exist in the fluid hose and in the gun.
5. Lock the safety lever on the gun.
6. Remove the siphon kit from the spray
material.
6 / 12
CLEANING YOUR BINKS PUMP
CAUTION
!
Do not allow spray material or solvent
to soak into the ground.
WARNING
!
Wear eye protection.
1. Clean the pump and the siphon kit
from the outside. Immerse the suction
system in the tank of solvent.
2. Clean the fluid tip/ tip system as
described in the service bulletin of the
spray gun. We recommend to soak the
fluid tip in solvent.
3. Unlock the safety lever of the gun
without fluid tip. Operate the gun.
Close the high pressure ball valve. Set
the air inlet pressure to 1 bar (14.5 psi)
and slowly open the ball valve. Let the
solvent run through the system so that
the spraying material can rinse out.
4. Let the solvent run through the system
for a couple of minutes until the
solvent runs clear through the gun.
Close the ball valve and lock the safety
lever of the gun
5. Clean the gun from the outside and
check the filter on the handle (if
mounted).
6. Clean the filter element of the high
pressure filter.
7. Clean the filter of the siphon kit.
8. We recommend keeping the pump
filled with liquid.
NOTE
If the pump is not to be used for longer
periods of time, we recommend flushing
the system with a light, silicone-free oil.
77-2919-R6.3 (8/2015)