Connect Vent System; Make Electrical Connection - IKEA LIB0119520B Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Connect Vent System

1. Install vent system.
2. Push duct over the exhaust outlet. Seal all connections
with vent clamps.
3. Use caulk to seal all openings.

Make Electrical Connection

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Remove terminal box cover using a T10 Torx
(or T10 adapter provided) to remove the screws.
3. Remove the knockout in the terminal box and install
a UL listed or CSA approved
A
A. Terminal box
B. Knockout
C. Terminal box cover
10
drive
®
/
" strain relief.
1
2
B
C
4. Run home power supply cable through strain relief
into terminal box.
A
C
D
E
A. Home power supply cable
B. UL listed or CSA
approved strain relief
C. Black wires
5. Use UL listed wire connectors and connect
black wires (C) together.
6. Use UL listed wire connectors and connect
white wires (E) together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
7. Connect green (or bare) ground wire from home power
supply to yellow-green ground wire (F) in terminal box
using UL listed wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Check that all light bulbs are secure in their sockets.
11. Reconnect power.
B
F
D. UL listed wire connectors
E. White wires
F. Green (or bare) and
yellow-green ground wires