Technical Specifications; Simple Troubleshooting - Thermador TCM24TS Guía De Uso Y Cuidado

Ocultar thumbs Ver también para TCM24TS:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

en

Technical specifications

Technical specifications
Power connection with transformer type 8001010566
(voltage – frequency)
Power rating
Maximum static pump pressure
Maximum water tank capacity (without filter)
Maximum capacity of the coffee bean container
Length of power cable (Power socket – transformer)
Dimensions (appliance without transformer) H x B x D
Weight, empty (appliance without transformer)
Dimensions (only transformer) H x B x D
Weight (only transformer)
Type of grinding unit

Simple troubleshooting

The following table provides solutions for problems that may arise as you use your
Thermador machine. If you do not find a solution for your specific problem or the problem
persists after troubleshooting, please contact 1-800-944-2904.
Problem
Strongly fluctuating coffee
or milk froth quality (e�g�
fluctuation in quantity or milk
froth spraying)�
Drinks cannot be dispensed. Beverage outlet or one of the
The drink runs out at
the entire outlet during
dispensing�
Too little milk froth, none at
all, or the milk system is not
taking in any milk�
30
Cause
Build-up of limescale in the
appliance�
The suction pipe is blocked.
3 connections are blocked.
Lower part of the beverage
outlet is missing�
Build-up of limescale in the
appliance�
Beverage outlet or one of the
3 connections are blocked.
Milk not suitable for foaming. Do not use milk that has already
Beverage outlet or the milk
tubes are not correctly
assembled.
The suction pipe is blocked.
120 V AC – 60 Hz
1600 W
19 bar
81�15 oz (2�4 l)
1 lb (500 g)
39" (1 m)
17 7/8" x 23 3/8" x 14 3/4"
(455 x 596 x 375 mm)
42-44 lb (19-20 kg)
8 1/4" x 6 3/4" x 6 3/4"
(210 x 172 x 198 mm)
27.55 lb (12.5 kg)
Ceramic
Solution
Descale the appliance according
to the instructions, see the
section "Service programs".
Clean the suction pipe�
Clean the beverage outlet and
the connections�
Attach the lower part, see the
section "Cleaning the milk
system".
Descale the appliance according
to the instructions, see the
section "Service programs".
Clean the beverage outlet and
the connections�
been boiled. Use cold milk with a
fat content of at least 1�5%�
Moisten the individual parts and
put them together again�
Clean the suction pipe�

Publicidad

Tabla de contenido
loading

Tabla de contenido