Changing The Spark Plug; Transportation And Storage - Generac iX 1600 El Manual Del Propietario

Ocultar thumbs Ver también para iX 1600:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CHANGING THE SPARK PLUG

Replace the spark plug each year, regardless of how many hours
the generator has been run. Use a NGK BPR7HS that has be
gapped to .030" (.76mm). To replace the spark plug:
1. Remove the spark plug cover on the top right side of the
generator, just below the handle (Figure 12).
2. Carefully pull the spark plug lead from the spark plug. Use a
socket wrench to remove the spark plug.
3. Install the new spark plug into the cylinder head. Tighten the
spark plug to 15 ft/lb.
4. Replace the spark plug lead, making sure it is fully seated.
5. Replace the spark plug cover.
Figure 12 - Replace Spark Plug
SPARK PLUG
LOCATION

TRANSPORTATION AND STORAGE

Transport or store the generator only if it has cooled completely.
Make sure the fuel valve and the vent on the fuel cap are both in
the OFF ("O") position.
It is important to prevent gum deposits from forming in essential
fuel system parts such as the carburetor, fuel hose or tank during
long-term storage. Also, experience indicates that alcohol-blended
fuels (called gasohol, ethanol or methanol) can attract moisture,
which leads to separation and formation of acids; these acids gas
can damage the fuel system of an engine while in storage.
To avoid engine problems, the use of a commercial fuel stabilizer
prior to storage is recommended. Follow the manufacturer's
instructions when adding the fuel stabilizer.
If the generator is going to be stored for more than six (6) months,
the generator should be prepared as follows:
1. Remove all gasoline from the fuel tank.
2. Start and run engine until engine stops from lack of fuel or open
the valve on carburetor bowl (Figure 13), and allow gasoline
to drain down tube into a receptacle. Discard appropriately. Be
sure to close the valve once the gasoline has drained.
Figure 13 - Carburetor Drain Valve
CARBUREATOR DRAIN
VALVE LOCATED BEHIND
AIR INTAKE
TURN VALVE COUNTER-
CLOCKWISE TO DRAIN FUEL,
CLOCKWISE TO CLOSE
3. While engine is still warm, drain oil from crankcase. Refill with
recommended grade.
4. Remove spark plugs and pour about 1/2 ounce (15 ml) of
engine oil into the cylinders. Cover spark plug hole with rag.
Pull the starting rope several times to coat the cylinder walls
with engine oil.
5. Install and tighten the spark plug.
6. Clean the generator outer surfaces. Check that cooling air
slots and openings on generator are open and unobstructed.
7. Store the unit in a clean, dry place.
Do not store gasoline from one season to another.
If possible, store the unit indoors and cover it to give protection
from dust and dirt.
Maintenance
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

005792-2

Tabla de contenido