Configuration Menu
Press the DHW buttons together for 10 seconds to access the configuration Menu. 7 pa-
rameters are available, indicated by the letter "b", which are not modifiable from Remote
Timer Control.
Press the Heating buttons to scroll the list of parameters in increasing or decreasing or-
der. Press the DHW buttons to view or modify the value of a parameter: the modification
will be automatically saved.
Contents Description
Range
0=Natural Gas
b01
Gas type selection
1=LPG
1=Bithermal instantaneous
2=Monothermal instantaneous
b02
Boiler type selection
3=Heating only (3-way valve)
4=Heating only (circulating
pump)
0=Sealed Chamber combus-
tion control
(without fume pressure switch)
1=Open Chamber (with fume
thermostat)
2=Sealed Chamber (with fume
pressure switch)
Combustion cham-
3=Sealed Chamber combus-
b03
ber type selection
tion control
(with fume thermostat on recu-
perator)
4=LOW NOx Sealed Chamber
Combustion control
(without fume pressure switch)
5=LOW NOx Open Chamber
(with fume thermostat)
0=Flat
Primary Exchanger
type selection
1=Omega
(b03=0)
2=--
No effect on adjust-
ment (b03=1)
No effect on adjust-
ment (b03=2)
b04
0=Flat
Primary Exchanger
type selection
1=Omega
(b03=3)
2=--
No effect on adjust-
--
ment (b03=4)
No effect on adjust-
--
ment (b03=5)
0=External gas valve
Relay card LC32
operation selection
1=System filling solenoid valve
(b02=1)
2=Solar 3-way valve
No effect on adjust-
b05
ment (b02=2)
No effect on adjust-
ment (b02=3)
No effect on adjust-
ment (b02=4)
0=50Hz
Mains Voltage Fre-
b06
quency
1=60Hz
Comfort burner on
time
0-20 seconds
(b02=1)
No effect on adjust-
ment (b02=2)
b07
No effect on adjust-
ment (b02=3)
No effect on adjust-
ment (b02=4)
Notes:
1.
Parameters with more than one description vary their function and/or range in rela-
tion to the setting of the parameter given in brackets.
2.
Parameters with more than one description are reset to the default value if the pa-
rameter given in brackets is modified.
To exit the configuration Menu press the DHW buttons together for 10 seconds, or exiting
occurs automatically after 2 minutes.
Default
CLIZIA D LOW NOX 24 AS
0=Natural
0=Natural Gas
Gas
1=Bither-
mal instan-
2=Monothermal instantaneous
taneous
0=Sealed
Chamber
4=LOW NOx Sealed Chamber
with
Combustion control
combus-
(without fume pressure switch)
tion control
0=Flat
0=Flat
--
0
--
0
0=Flat
0
0
0=External
0=External gas valve
gas valve
--
0
--
0
--
0
0=50Hz
0=50Hz
5 seconds
5 seconds
--
5
--
5
--
5
cod. 3541D120 - Rev. 00 - 10/2012
Service menu
The card Service Menu is accessed by pressing the Reset button for 20 seconds. 4 sub-
menus are available: press the Heating buttons to select, in increasing or decreasing or-
der, "tS", "In", "Hi" or "rE". "tS" means Transparent Parameters Menu, "In" means
Information Menu, "Hi" means History Menu: after selecting the submenu, press the Re-
set button again to access it; "rE" means History Menu Reset: see description.
"tS" - Transparent Parameters Menu
16 parameters indicated by the letter "P" are available: which are also modifiable from
Remote Timer Control.
Press the Heating buttons to scroll the list of parameters in increasing or decreasing or-
der. Press the DHW buttons to view or modify the value of a parameter: the modification
will be automatically saved.
Contents
Description
Range
P01
Ignition ramp Offset
0-40
P02
Heating ramp
1-20°C/minute
P03
Heating standby time 0-10 minutes
Heating Post-Circula-
P04
0-20 minutes
tion
Heating user max.
P05
31-85°C
setpoint
Max. power in heat-
P06
0-100%
ing
0=Fixed
1=Linked to set point
Burner shutdown in
hot water production
2=Solar (5)
(b02=1)
3=Solar (10)
4=Solar (20)
0=Fixed
1=Linked to set point
P07
Burner shutdown in
hot water production
2=Solar (5)
(b02=2)
3=Solar (10)
4=Solar (20)
Hot water tank hys-
0-4°C
teresis (b02=3)
Hot water tank hys-
0-4°C
teresis (b02=4)
DHW standby time
0-60 seconds
(b02=1)
DHW standby time
0-60 seconds
(b02=2)
P08
DHW standby time
0-60 seconds
(b02=3)
DHW standby time
0-60 seconds
(b02=4)
DHW user max. set
50-65°C
point (b02=1)
DHW user max. set
50-65°C
point (b02=2)
P09
DHW user max. set
50-65°C
point (b02=3)
DHW user max. set
50-65°C
point (b02=4)
Anti-inertia function
70-85°C
temperature (b02=1)
No effect on adjust-
--
ment (b02=2)
Delivery temperature
P10
in hot water produc-
70-85°C
tion (b02=3)
Delivery temperature
in hot water produc-
70-85°C
tion (b02=4)
Anti-inertia function
Post-Circulation
0-5 Seconds
(b02=1)
DHW Post-Circula-
0-60 Seconds
tion (b02=2)
P11
DHW Post-Circula-
0-60 Seconds
tion (b02=3)
DHW Post-Circula-
0-60 Seconds
tion (b02=4)
P12
Max. power in DHW
0-100%
P13
Absolute min. power
0-100%
0=Default
P14
Post-Ventilation
1=50 seconds
CLIZIA D LOW NOX
Default
24 AS
10
10
5°C/minute
5°C/minute
2 minutes
2 minutes
6 minutes
6 minutes
80°C
80°C
100%
100%
0=Fixed
0=Fixed
0=Fixed
2°C
2°C
30 seconds
60 seconds
60 seconds
30 seconds
30 seconds
50°C
55°C
55°C
65°C
65°C
70°C
0
0
80°C
80°C
0 seconds
30 seconds
30 seconds
30 seconds
30 seconds
100%
100%
0%
0%
0=Default
0=Default
17