Packing And Unpacking; Setting To Work - Connection To The Power Supply; Extensions - Nilfisk Alto ATTIX 200 Instrucciones De Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Packing and unpacking

Dispose of the packing materials in compliance with the laws in force.
Model
A (mm)
B (mm)
C (mm)
Weight (kg)

Setting to work - connection to the power supply

DANGER !
Make sure that the vacuum cleaner is in perfect
condition before starting work.
Before plugging the vacuum cleaner into the electrical
mains, make sure that the voltage rating indicated
on the data plate corresponds to that of the electrical
mains.
Plug the vacuum cleaner into a socket with a correctly
installed ground contact/connection. Make sure that
the vacuum cleaner is off.
The plugs and connectors of the connection cables
must be protected against splashed water.
Make sure that connections to the electrical mains and
plug are correct.
Use the vacuum cleaners only when the cables that
connect to the electrical mains are in perfect condition
(damaged cables could lead to electric shocks!).
Regularly check that the electric cable does not show
signs of damage, excessive wear, cracks or ageing.
DANGER !
When the vacuum cleaner is operating, do not:
Crush, pull, damage or tread on the cable that
connects to the electrical mains.
Only disconnect the cable from the electrical mains by
removing the plug (do not pull the cable).
Only replace the electric power cable with one of the
same type as the original (HO7 RN - F); the same rule
applies if an extension is used.
The cable must be replaced by the manufacturer's
Service Centre staff or by equivalent qualified
personnel.
11/2008
Figure 2
Nylon packing
ATTIX200 - M
ATTIX200 - H
1,700
900
1,950
333

Extensions

If an extension cable is used, make sure it is fit for the power
draw and protection degree of the vacuum cleaner.
DANGER !
Type 22 variant: extensions, plugged in electrical devices
and adapters cannot be used when the vacuum cleaner is
used for flammable dust.
Minimum section of extension cable L = 20 m max.
Cable = HO7 RN - F.
Max power (kW)
Minimum section (mm
DANGER !
Sockets, plugs, connectors and installation of the
extension cable must maintain the IP protection degree of
the vacuum cleaner, as indicated on the data plate.
DANGER !
The vacuum cleaner's power socket must be protected
by a differential circuit-breaker with surge current
limitation, that shuts off the power supply when the current
discharged to the ground exceeds 30 mA for 30 msec. or an
equivalent protection circuit.
DANGER !
Never spray water on the vacuum cleaner: this could be
dangerous for persons and could short circuit the power
supply.
Consult the latest edition of the European Union Directives,
the Laws in the country of use and the current standards
in force (UNI - CEI - EN), particularly European standard
EN60335-2-69.
5
3
5
)
2.5
4
2
ATTIX 200
15
22
10
16
I
GB
F
D
E
C329

Publicidad

Tabla de contenido
loading

Tabla de contenido