Technical Data - Riello F5 Instrucciones Para La Instalación, Uso Y Mantenimiento

Ocultar thumbs Ver también para F5:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TECHNICAL DATA

TYPE
Thermal power – Output
Fuel
Electrical supply
Motor
Capacitor
Ignition transformer
Pump
Absorbed electrical power
Burner with CE marking in conformity with EEC directives: EMC 2004/108/CE,
Low Voltage 2006/95/CE, and Machines 2006/42/CE.
The burner meets protection level of IP 40, EN 60529 .
9
4
3
1 – Return line
2 – Suction line
3 – Gauge connection
4 – Pump pressure regulator
5 – Vacuum gauge connection
6 – Screws fixing air-damper
7 – Air-damper
8 – Combustion head adjustment screw
9 – Lock-out lamp and reset button
10 – Flange with insulating gaskets
2393
461T58
30 – 60 kW
Light oil, viscosity 4 – 6 mm
Single phase, 220 V + 10 % – 15 %
Run current 1 A – 3300 rpm – 345 rad/s
2.5 F
Secondary 8 kV – 16 mA
Pressure: 8 – 15 bar
0.18 kW
Fig. 1
7
6
6
10
D8070
1
GB
2.5 – 5 kg/h
2
/s at 20 °C
~
60Hz
2
ENGLISH
8
1
5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

461t583746159

Tabla de contenido