Faqs / Troubleshooting; Compression Pump - VITO PRO-POWER VICOC300A Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
Question/Problem
The engine doesn't start or runs too slow:
• No power voltage;
• Too low power voltage;
• Thermal protection triggers;
• Too low temperature;
• Failure in the pressure switch;
• Failure in the engine;
The compressor works but doesn't have
enough pressure or has a low discharge
capacity:
• The air filter is clogged;
• Leak in the non-return or safety valve;
• Leak in the compressed air pipes;
• Damaged joints;
• Leak in the condensed water purging screw;
• Damaged cylinder and segments;
The engine stops abruptly:
• Damaged moving parts due to low oil level in the

compression pump;

• Damaged or blocked moving parts;
The compressor stops and thermal
protection triggers:
• Engine overheat;
• Rotating parts are blocked or damaged, provoking
the overheat;
The compressor is running, the pressure is
shown in the manometer but the tools aren't
responding:
• Leak in the compressed air hose;
• Leaks in the quick joints;
• The pressure defined in the regulator is too low;
Too much oil consumption:
• The oil level is too high;
• Damaged cylinder or segment;
Abnormal noise or vibration:
• Loosen parts or connecting accessories;
• Strange elements inside the engine;
• Damaged joints;
• Damaged moving parts;
40

9. FAQS / TROUBLESHOOTING

Solution
• Check the power cable, connecting plug, socket and circuit
breaker;
• Avoid long extension cords;
Use an extension cord with enough transversal section;
• Press thermal contactor's "Reset" button;
• Do not use the compressor with an exterior temperature
lower than +5°C;
• Repair or replace;
• Repair or replace;
• Clean or replace;
• Check and repair the valves;
• Check or repair;
• Replace the damaged joints;
• Tighten the screw manually;
Check the screw's joint and, if necessary, replace it;
• Repair or replace;
• Check the moving parts status and replace them if
necessary;
• Repair or replace the damaged parts;
• Allow the compressor to cool down, press the thermal
protection trigger button and switch the compressor on;
• Unclog or replace the parts, press the thermal protection
trigger button and turn the compressor back on;
• Check the compressed air hose and tools. Replace them if
necessary;
• Check the quick joint and replace it if necessary;
• Increase the pressure using the pressure regulator;
• Check and adjust the oil level;
• Repair or replace;
• Check and tighten;
• Check and clean;
• Replace the damaged joints;
• Repair or replace;

Publicidad

Tabla de contenido
loading

Tabla de contenido