5.6 - COSTE SENSIBILI
The CITY4-EVO control unit is equipped with an input capable of
managing both the classic rib with contact normally closed and
the conductive rubber rib with nominal resistance of 8.2 kohm.
• Connect the cables of the safety ribbons between terminals
L7 and L11
C
To activate the function, change the settings of
CoSt
parameter
L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11
In order to meet the requirements of the EN12978 rules, it is
necessary to install safety edges controlled by a control unit
continuously checking the proper working. If using control units
suited to the test by power outage, connect the power supply
cables of the control unit between terminals Z3 and Z2 of the
control unit.
Otherwise, connect them between terminals Z1 and Z2.
m
WARNING:
• Make use of safety edges having outputs with normally close
contact.
• Outputs of same kind safety edges must be connected in
series.
5.7 - LIMIT SWITCHES
The CITY4-EVO unit can control the gate run through a limit
switches.
The limit swiches can be used for indicating the limits of the run
or to indicate the start of the slowdown point.
C
To activate the function and select the type of operation
(limits of run/start of slowdown) change the settings of the
FC.En
parameter.
Connect the limit switch to the unit terminal box as follows:
• opening limit switch in door 1 between terminal L9 and L11
• closing limit switch in door 1 between terminal L10 and L11
L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11
FCA
FCC
5.8 - ENCODER
With CITY4-EVO, you can use encoder-equipped motors to
control the exact position of the gates. Furthermore, the encoders
allow you to detect if the gate panels jam in an improper position
due to obstacles.
m
To operate the encoder, it is indispensable for the door
in the closure position to rest on the mechanical stop.
Upon every switching on of the control unit, the first START
control closes the gate to realign the encoders (if automatic
closing is active this operation occurs automatically).
m
ATTENTION: Limit switches entry terminals are used to
connect the encoders. It is not possible to simultaneously
connect the encoder and limit switch.
m
WARNING: the sensor cables must not be run in the
same conduit as the motor cables.
m
WARNING: the encoders must be connected as
indicated below. Improper connection of the black cable
may damage the device.
• Connect the negative feeds (BLACK cable) for both encoders to
terminal L11
• Connect the positive feeds (RED cable) for both encoders to
terminal Z5
• Connect the motor 1 encoder signal cables (BLUE / WHITE) to
terminals L9 and L10
C
To activate the function, change the settings of parameter
EnCo
L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11
ENCODER
5.9 - FLASHING LIGHT
CITY4-EVO provides for a 230V - 40W (120V – 40W for 120V
model) flashing light equipped with intermittence inside.
Connect flashing light cables to terminals G6 and G7 of the
control unit.
G1 G2 G3 G4 G5 G6 G7
- 36 -
Z1 Z2 Z3 Z4 Z5 Z6
12Vdc
230V - 40W