Emergency Dead Man Operation; Programming The Control Unit - V2 CITY4-EVO Manual De Instrucciones

Ocultar thumbs Ver también para CITY4-EVO:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

15 - EMERGENCY DEAD MAN
OPERATION
This operational mode can be used to move the gate in DEAD
MAN mode in particular cases, such as installation/maintenance or
in the case of malfunctioning of photocell, edge, limit switches or
encoder.
To activate the function the START command must be pressed
3 times (presses must last at least 1 second; the pause between
commands must last at least 1 second).
1"
1"
>1"
The fourth START command activates the gate in MAN PRESENT
mode. To move the gate keep the START command pressed for
the duration of the operation (time T).
The function will automatically turn off after 10 seconds of
inactivity of the gate.
Strt
NOTE: if the
parameter is set as
command (from the terminal block or remote control) moves the
gate in the open and closed directions alternatively (unlike the
normal DEAD MAN mode).
1"
T
>1"
>1"
StAn
, the Start
16 - CONTROL UNIT
CONFIGURATION
Control unit time and function programming is made within a
special configuration menu, to which you can access and where
you can shift through DOWN, MENU and UP keys placed under
the display.
The configuration menu consists in a list of configurable items;
the display shows the selected item.
• By pressing DOWN, you will pass to the next item
• By pressing UP, you will return to the previous item
• By pressing MENU, you can view the current value of selected
item and possibly change it.
Based on the requirements of the installation, it is possible to
activate the SHORT or FULL programming menu.
The SHORT menu consists only of parameters useful for a
programming base, while the FULL menu consists of all the
parameters of the programming menu (the parameters present
only in the FULL menu are shown in the table).
To activate the SHORT programming menu hold the MENU key
until the display shows
displays the first parameter of the
To activate the FULL programming menu hold the MENU key until
-Pr.F
the display shows
the first parameter of the
FinE
The last menu item (
and going back to the control unit normal operation.
You must exit from programming mode through this menu item if
you do not want to lose your configuration.
m
WARNING: in case no operation is carried out for
more than one minute, the control unit exits from the
programming mode without saving any of your setups and
changes, which will get lost.
NOTE: By holding pressed the UP key the programming menu
parameters scroll fast backwards until item
By pressing key DOWN the programming menu parameters scroll
FinE
fast forward until item
3"
MENU
- 45 -
-Pr.S
; by releasing the key, the unit
En.SA
menu.
; by releasing the key, the unit displays
En.SA
menu.
) allows storing the carried out changes
En.SA
is displayed.
is displayed.
3"

Publicidad

Tabla de contenido
loading

Tabla de contenido