5.10 - COURTESY LIGHTS
Thanks to the output COURTESY LIGHT the control unit City4
allows the connection of an electric appliance (e.g. courtesy light
or garden lights), controlled automatically or by means of the
special transmitter key.
The output COURTESY LIGHT is a simple N.O. contact with no
power supply.
Connect the cables to terminals G1 and G2.
V
SUPPLY
The functions depend on programming of the
AUS
and the
parameter.
To set the functions, you need to program the
follows:
t.LUC
: The relay closes when a command or remote control
arrives with Start or Start Pedestrian and it opens after
the time set.
CiCL
:
The relay remains closed for the entire duration of the
opening/closure cycle. If a remote control arrives on
channel 4, it remains closed for the time set on the item
t.LUC
.
AUS
By editing the
parameter settings, the COURTESY LIGHT
output can be set as an auxiliary output to which one of the
following functioning logics can be associated:
Mon
- MONO-STABILE: the relay remains closed until the
remote control signal on channel 4 arrives.
biSt
- BI-STABILE: the relay changes status each time a remote
control on channel 4 arrives.
tiM
- TIMER: the relay is closed when a remote control arrives
on channel 4 and opens after the time set
toUt
- BI-STABILE+TIMER: the relay is closed when a remote
control arrives on channel 4 and opens after the time set.
If a second remote control reaches channel 4 before the
time is up, the relay opens.
G1 G2 G3 G4 G5 G6 G7
LUCi
parameter
LUCi
parameter as
5.11 - LOW VOLTAGE LIGHT
The control unit has a 12Vdc output that allows connections to a
load up to 3W.
This output can be used to connect a signal light that indicates
that status of the gate, or for a low voltage flashing light.
Connect the low voltage signal light or flashing light wires to
terminals Z5 (+) and Z6 (-).
C
To activate the function, change the settings of parameter
SPiA
Z1 Z2 Z3 Z4 Z5 Z6
m
CAUTION: Pay attention to the polarity of the
connected device if necessary
5.11 - LOCK
An electric lock can be assembled on the gate to ensure good
closure of the door.
Make use of a 12V lock.
Connect lock cables to terminals Z4 and Z5 of the control unit.
C
To modify the times of action of the lock, check the settings
of the following parameters:
t.SEr
-
lock time
t.ASE
-
advanced lock time
If the electric lock has difficulties in the early stages of release or
engagement, there are functions to facilitate these operations:
1. Backlash time: before starting motor opening, it is piloted in
closure to facilitate release of the lock.
C
To activate this function set the ram hammering time
t.inv
through the
2. Fast closing time after slowdown: once completed the
slowdown stage, the unit orders closing at normal speed
(without slowdown) to facilitate engagement of the lock.
C
To activate this function, set the fast closing time through
t.CvE
the
parameter
- 37 -
12Vdc - 3W
parameter
Z1 Z2 Z3 Z4 Z5 Z6
12V