17. Replacing the Flow Rate Regulator
17.1 Close the corner valve (c).
17.2 Trigger the valve.
17.3 Unscrew the connector hose (a) from the connector piece (b).
17.4 Unscrew the connector piece (b) from the corner valve (b).
17.5 Press the flow rate controller (d) out of the connector piece and replace it.
17.6 Reassemble in the reverse order.
18. Replacing the Solenoid Valve Cartridge
18.1 Close the corner valves.
18.2 Trigger the valve.
18.3 Loosen the screw (a) with a hollow hexagon wrench.
18.4 Pull the housing (b) from the base (c).
18.5 Remove the screws (d).
18.6 Remove the mounting bracket (e).
18.7 Remove and replace the solenoid valve cartridge (f).
18.8 Reassemble in the reverse order.