ASSEMBLY
• All new tanks must be purged of air and moisture
prior to filling. Used tanks that have not been plugged
or kept closed must also be purged. The purging
process should be done by a propane supplier (Tanks
from an exchange supplier should have been purged
and filled properly).
• Always position the tank so the connection between
the valve and the gas inlet will not cause sharp bends
or kinks in the hose.
Explosion hazard. Do not start generator if you smell
LPG. Always fully close the propane tank valve and
disconnect the LPG/propane hose from the generator
when not in use.
1. Turn the generator OFF and place on a flat surface in a
well ventilated area.
2. Verify that the propane tank valve is in the fully closed
position.
3. Remove the cover on the generator propane inlet valve.
4. Use your fingers to hand thread the LPG/propane hose
(included) to the propane inlet on the generator.
IMPORTANT: DO NOT use thread seal tape or any other
type of sealant to seal the LPG/propane
hose connection.
5. Tighten the LPG/propane hose connector to the
generator with a 19 mm or adjustable wrench. DO NOT
over-tighten.
Torque: 5-10 lb-ft.
6. Remove the safety plug or cap from the propane tank
valve.
7. Attach the other end of the hose to the LPG/propane
connector on the tank and hand tighten.
8. Turn the propane tank valve to the fully open position.
Check all connections for leaks by wetting the fittings
with a solution of soap and water. Bubbles which appear
or bubbles which grow indicate that a leak exists. If a
leak exists at a fitting, turn the propane tank valve to
the fully closed position and tighten the fitting. Turn the
valve back on and recheck the fitting with the soap and
water solution. If the leak continues or if the leak is not
at a fitting then do not use the generator and contact
customer service.
NOTICE
WARNING

CONNECT THE BATTERY

1. Push down the battery access cover tab and pull the
cover forward to remove it.
2. Verify that the rubber battery strap is firmly securing the
battery in place. If loose, pull on the strap and hook it
onto the mounting base.
Note: If the strap is loose behind the battery, remove the
battery, reconnect the strap, replace the battery,
then thread the strap under the battery quick
connect cables.
Battery Strap
Mounting Base
3. A quick-connect battery plug is pre-installed on the
battery. Remove the cable tie securing the plugs then
push firmly to connect them.
4.
Align the tabs on the bottom of the battery access cover
with the generator case then push to reinstall the cover.
Note: The generator is equipped with a battery charging
feature. Once the engine is running, a small charge
will slowly recharge the battery.
Westinghouse Outdoor Power Equipment, LLC | 13
Battery Access
Cover Tab