FEATURES
CONTROL PANEL COMPONENTS
17
18
19
20
1. 120 Volt AC, 20 Amp Duplex NEMA 5-20R
Receptacle: Receptacle can supply a maximum of
20 Amps.
2. Ground Terminal: The ground terminal is used to
externally ground the generator.
3. Parallel
Operation
Westinghouse Inverter Generator can be connected
for additional power output.
4. LED Data Center: Displays remaining run time (F),
power output in kW (P), fuel level in liters (L), voltage
output (V), and lifetime hours.
5. Overload Reset: The generator inverter will
automatically switch OFF all AC output to protect
the generator if overloaded or if there is a short
circuit in a connected appliance.
6. USB Ports: Two-port 5V/2.1A USB outlet. Accepts
Type A USB plugs.
7. Low Oil LED: Indicates low oil level. When the oil
level in the crankcase falls below the safe operating
limit, the low oil level indicator will illuminate and the
generator will automatically shut off the engine.
8. Overload LED: Indicates that the generator is
overloaded. See page 17.
9. Output Ready LED: Illuminates when the generator
is operating normally. Indicates the generator is
producing electrical power at the receptacles.
10 | Westinghouse Outdoor Power Equipment, LLC
16
15
1
Outlets:
A
compatible
14
13
12
2
3
10. Fuel Selector Switch: Used to select gas or propane
operation.
11. LPG/Propane Inlet: Connects a propane tank with
the included LPG/propane hose.
12. Battery Charging Port: Used to charge the battery
with the included battery charger.
13. Battery Indicator: Indicates that battery power is
ON. Light will remain illuminated while the unit is ON.
14. Eco Mode: Eco mode minimizes fuel consumption
and noise by adjusting the engine RPM to the
minimum required for the current load.
15. Push-Button
automatically start the engine. Push again to stop
the engine.
16. Battery Switch: Turns battery ON and OFF. Must be
ON before electric start or remote start.
17. Main Circuit Breaker: The main circuit breaker
controls total output of all outlets to protect the
generator from overload or short circuit.
18. 20 Amp AC Circuit Breaker: Circuit breaker limits
the current that can be delivered through the NEMA
5-20R receptacle to 20 Amps.
19. 30 Amp AC Circuit Breaker: Circuit breaker limits
the current that can be delivered through the NEMA
TT-30 receptacle to 30 Amps.
20. 120 Volt AC, 30 Amp NEMA TT-30R Receptacle:
Receptacle can supply a maximum of 30 Amps.
11
10
5
4
Start/Stop:
9
8
7 7
6
Push
once
to