Light will not come
on after power
failure
Loss of signal
Moves slow
No flash
No laser output
No light output
Relay doesn't work Check the reset switch. Check all cable connections.
Remote control
does not work
Stand alone mode
Design and product specifications are subject to change without prior notice.
Some discharge lamps require a cooling off period,
before the electronics in the fixture can kick start
it again. Wait 5 to 10 minutes before the lamp is
cooled off and then power it up again.
Use only proper DMX cables. Install a 120Ω termi-
nator on the last device. Note: Keep DMX cables
separated from power cables or black lights.
Check the 220/110v switch for proper setting.
Re-install the bulb, it may have shifted during ship-
ping.
The bounce mirror motor may have shifted during
shipping, readjust it accordingly.
Install a new bulb. Fixture is too hot:
-Allow fixture to cool.
-Clean fan.
-Make sure air vents at control panel and front lens
are not blocked.
-Turn up the air conditioning The power supply
settings do not match local AC voltage and frequen-
cy. Disconnect fixture. Check settings and correct if
necessary. Contact a technician for servicing, if the
problem persists.
Make sure the connector is firmly connected to the
device.
All Tecshow lighting fixtures featuring stand-alone
functions do not require additional settings, simply
power up the fixture and it will automatically enter
the stand-alone mode.