REPLACEMENT OF BURNER
INJECTORS
If the injectors are not supplied they
can be obtained from the "Service
Centre".
Select the injectors to be replaced
according to the "Table for the choice of
the injectors".
To replace the injectors proceed as fol-
lows:
- Remove pan supports and burners
from the cooktop.
- Using a wrench, substitute the nozzle
injectors "J" (figs. 8.11, 8.12) with
those most suitable for the kind of
gas for which it is to be used.
ADJUSTING OF THE MINIMUM OF
THE TOP BURNERS
In the minimum position the flame must
have a length of about 4 mm and must
remain lit even with a quick turn from the
maximum position to that of minimum.
The flame adjustment is done in the fol-
lowing way:
– Turn on the burner
– Turn the tap to the MINIMUM position
– Take off the knob
– With a thin screwdriver turn the screw
F until adjustment is correct (fig. 8.13).
Normally for LPG, the regulation
screw is tightened up.
LUBRICATION OF THE GAS TAPS
In case of difficulty in the gas taps
operation, call Service.
IMPORTANT
All intervention regarding installation maintenance of the appliance must be
fulfilled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.
Gas maintenance
Fig. 8.13
F
J
Fig. 8.11
J
255