User's Guide
tare
Put the package on the scale and press
weight has been deducted. After removing all items and package form the scale, if there is a display of weight of package in a negative
number on the weight space, press the key
Pieces number set
Put samples of the products on the scale. The weight screen will show the weight. Press numeral key to input sample number and the
unit weight will display this number.
If press incorrectly, you can press
Now the unit weight screen, shows samples's unit weight and the total quantity display screen shows the sample's quantity. Then you
can sart counting now.
unit WeigHt set
Counting
When counting, if you already know the unit weigh of the product, you can press the numeral key to input tje unit weight directly. And
when you put the product on the scale, the total quantity screen will display the prduct's total quantity.
tare Presetting
If you already know the tare of the product, then after pressing
point, the weight screen will show the presetted unit weight. And automatically the weighed product has already been tared. You can
also press
clear the presetted tare.
accumulation
In weighing and couting mode, press
unit weight screen displays accumulated number. You can accumulate the next number after taking the accumulated product off and
the screen back to zero.
Press
to see the accumulated records and press it once again back to the normal weighing and numbering mode. Under the state
of accumulating display, you can press
Warming Presetting
When counting, if you want to set the upper and lower limit, press the
tion "-HI-". Press the numeral key to input the upper limit value and display it in the unit weight screen. Then press
and go into the lower limit set. The weight screen shows the lower set information "-Lo-". And press the numeral key to input the lower
limit value and display it in the total quantity screen. Then press
counting, suppose the quantity of the product is between the upper and the lower limit, buzzer will buzz to alarm.
auto-averaging oPeration
1. Press and hold
AVER. With
ging.) Press
2. Put samples of the products on the scale for sampling. In the process of counting, if the additional quantity is less than sampling
quantity, the scale will auto-averaging with buzzing. Otherwise, the scale will terminate auto-averaging.
3. Only when sampling finished, can auto-averaging workable.
calibration
Press and hold
weight shows the weight needs calibration. If you need to change the calibrated weight value, you can press the numeral key to input
new calibrated weight value and display it in the unit weight screen. If you inout incorrectly, you can press
Put the corresponding weight and display it in the weight screen. Load the weight on the pan after it's steady, press
back out from calibration mode.
unit selection
Press de
for 5 seconds, then press
the set unit will be automatically stored when turning the machine on next time.
16
to return to zero, its weight can be eliminated, if there is a signal of
and input again. Press
to accumulate weight and total quantity. The weight screen displays accumulated weigh; the
to clear all the accumulated records.
before turning the scale on and turn ON the scale without empressing. Press
key , set the auto-averaging into "0" ("0" stands for allowing auto-averaging, "1" stands for forbidding auto-avera-
repeatedly until return to main screen.
turn on the scale. TOTAL QUANTITY screen shows the single-point calibration information "CAL" and the unit
to choose the desire unit such as g, kg, lb. Press the
Counting scale
and
and the weight will run back to zero.
to confirm and the unit weight will be automatically be computed.
input the tare value and press
key, then the weight screen will show the upper limit informa-
to confirm and back to the weighing and counting mode. When
Model DSC
, it indicates that the
again for confirmation. At this
again to confirm
repeatedly until screen shows
to clear it and input again.
to confirm and
again back to the counting mode,