Replace Brush & Belt
WARNING
To reduce the risk of electric shock, turn power switch off and disconnect plug from
electrical outlet before performing maintenance or troubleshooting checks.
1
Unplug vacuum, turn over and unscrew
six (6) Philips-head screws to remove
the bottom cover. Lift brush straight out.
3
Replace the Brush Roll and Belt by looping the Belt over the motor shaft and the
Brush Roll. Line up the end caps and pull the brush forward into place. This will
stretch the belt. Return bottom cover back on and replace the screws.
Clearing a Clog
1
Remove the hose
from the back of the
vacuum by twisting
it to the left. Remove
any debris that may
have gotten clogged.
Belt
End Cap
2
Check the Foot Hose on
the back of your vacuum
down towards the bottom.
If necessary, remove the
screw from the foot hose
and check for clogs.
2
Clean debris from Brush Roll. Inspect by
placing on its end and spin. The brush
roll should spin freely, multiple times by
one flick. If it doesn't, replace Brush Roll.
Check belt for wear or cuts and replace
if necessary.
3
Check the air passageway on
the bottom of your vacuum.
Remove the bottom cover and
the brush. Remove any debris.
www.BISSELL.com