Symbol

8.3.5 Menu description

List (Fig. A5)
<1.0.0.0>
Position
OPERATION
SERVICE
• Turn the rotary knob to adjust the setpoint. The
display changes to menu <1.0.0.0> and the set-
point starts flashing. Rotate the rotary knob fur-
ther (or use the arrows) to increase or decrease
the value.
• Press the rotary knob to confirm the change, the
display returns to the status page.
<2.0.0.0>
Position
OPERATION
SERVICE
• The available operating modes are „Speed con-
trol", „Constant pressure", „Variable pressure"
and P.I.D control.
<3.0.0.0>
Position
OPERATION
SERVICE
<4.0.0.0>
Position
OPERATION
SERVICE
• Menu „Information" displays measuring, device
and operating data (Fig. A6).
52
Description
When the arrow appears:
• Press the rotary knob to access the
submenu (e.g. 4000 -> 4100).
When the arrow „return" appears:
• Press the rotary knob to access the
next higher menu (e.g. 4150 ->
4100).
Switch 1
Description
OFF
Adjustment of the setpo-
int, possible for both
cases.
ON
Switch 1
Description
Reading of operating
OFF
modes only.
Setting of operating
ON
modes.
Switch 1
Description
OFF
Setting the pump
ON/OFF.
ON
Switch 1
Description
OFF
Read-only display of the
„Information" menu.
ON
<5.0.0.0>
Position
Switch 1
Read-only display of the
OPERATION
OFF
„Service" menu.
Setting for „Service"
SERVICE
ON
menu.
• Menu „Service" provides access to the converter
parameter setting.
<6.0.0.0>
Position
Switch 1
OPERATION
OFF
Display of the fault page.
SERVICE
ON
• If one or several defects occur, the defects page
appears.
The letter „E" followed by a three digit code
appears (see section 11).
<7.0.0.0>
Position
Switch 1
OPERATION
OFF
Display of „Access lock"
symbol.
SERVICE
ON
• The „Access lock" is available when switch 2 is in
the ON position.
CAUTION! Risk of material damage!
Inadequate setting changes may cause pump
operation faults which may lead to material dam-
age of the pump or installation.
• Settings in „SERVICE" mode should only be made
during commissioning and by qualified personnel
only.
Description
Description
Description
SALMSON 12/2013