Location Requirements - Haier ESA415N Guía De Uso Y Cuidado

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

LOCATION REQUIREMENTS

IMPORTANT: Observe all governing codes and ordinances. Check the location where the air
conditioner will be installed. Make sure you have everything necessary for correct installation.
The site of installation should provide:
• A grounded electrical outlet within 4 ft. (122 cm) of where the power cord exits the air
conditioner.
NOTE: Do not use an extension cord, plug adapter, surge protector or multi-outlet adapter.
• Free movement of air in the room to be cooled.
• A large enough opening for the air conditioner.
• Unit must not be installed in a through-the-wall sleeve.
NOTE: The outside cabinet louvers and air discharge must not be obstructed by bushes, trees,
etc. Air must be able to pass freely through the cabinet louvers.
WINDOW INSTALLATION
Window opening measurements: (See Fig. 1)
A. Width
B. Height
WARNING
• Electrical shock hazard
• Plug into a mating, grounded 3 prong outlet.
• Do not remove the ground prong from the power supply cord.
• Do not use a plug adapter, extension cord, surge protector, or multi-outlet adapter
• Failure to follow these instructions can result in injury, fire, or electrical shock.
PAGE 6
(See Fig. 1)
ESA415N, ESA418N, ESA424N
29-1/2" - 39"
19-1/8"
WIDTH
INSTALLATION REQUIREMENTS
Fig. 1
B-HEIGHT
WIDTH
A-WIDTH

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Esa418nEsa424n

Tabla de contenido