ACCESSORIES/REPLACEMENT ITEMS
Replacement Items
Air-inlet filter (4/pk)
Fine particle filter (4/pk)
Air supply tubing (6')
Air supply plug
Humidifier Chamber
Power Items
AC power cord (USA)
AC power cord (UK)
AC power cord (EU)
MAINTENANCE
DANGER
Electric shock hazard-Do not attempt to open or remove the cabinet; there are no user-serviceable components
inside. If service is required, contact your equipment provider for instructions on obtaining service. Opening or
attempting to service your device will void the warranty.
WARNING
Disconnect supply before servicing.
Pressure Accuracy–The SleepCube is designed to provide accurate pressure performance from the factory without
additional calibration. No routine service is required provided the device is used in accordance with the manufacturer's
directions.
NOTE–Some countries require periodic servicing and calibration of this kind of medical device. Contact your equipment
provider for further information.
Standard Air-Inlet Filter–Check the filter every 10 days and clean it if necessary. Replace the filter every 6 months or
sooner if it is damaged. The standard filter is designed to filter particles larger than 3.0 microns in size. The SleepCube
MUST have the standard filter in place during operation.
Optional Fine Particle Filter–Check the filter every 10 days and replace it if it is dirty or damaged; otherwise replace the
filter every 30 days. The optional fine particle filter is designed to filter particles as small as 0.3 microns in size.
CLEANING
WARNING
To avoid electric shock, always unplug the power cord from the wall outlet power source before cleaning.
CAUTION–Never rinse or place the device in water. Never allow liquids to get into or around any of the ports, switches or
air filter; doing so will result in product damage. If this occurs, do not use the device. Contact your equipment provider for
service.
Device Cabinet
1.
Unplug the SleepCube from the power source. Wipe the cabinet with a clean, damp cloth every few days to keep the
cabinet dust free.
2.
Allow the device to dry completely before plugging it into a power source.
Filters
Air-Inlet Filter
1.
The air-inlet filter should be checked every 10 days and cleaned as necessary. The filter is located in the rear of the
device.
CAUTION–Proper filter function is important for the operation of the device and to protect the device from damage.
SE-DV57-1
DV51D-602
Heater connection cover
DV51D-603
Oxygen adapter
CPAP-TUB 6 Carrying case
DV51D-604
Heated Humidifier
DV5C
Chamber Sealing Gasket
DV51D-606
AC power cord (Australia)
DV51D-608
DC power cord
DC battery clamp-on adapter (requires DC
DV51D-607
Power Cord DV51D-619)
DV51D-605
7353D-601
DV51D-610
DV5HH
DV5C-614
DV51D-609
DV51D-619
DV51D-696
EN - 11