Loading nailer
008393
Select nails suitable for your work. Depress the latch
lever and open the magazine cap.
Lift and turn the coil support plate so that the arrow with
nail size indicated on the coil support plate will point to
the corresponding graduation increment marked on the
magazine. If the tool is operated with the coil support
plate set to the wrong step, poor nail feed or malfunction
of the tool may result.
1
2
008394
Place the nail coil over the coil support plate. Uncoil
enough nails to reach the feed claw. Place the first nail in
the driver channel and the second nail in the feed claw.
Place other uncoiled nails on feeder body. Close the
magazine cap after checking to see that the nail coil is
set properly in the magazine.
008395
1. Magazine cap
1
2. Latch lever
2
1. Coil support
plate
2. Graduation
3. Arrow
3
1. Feed Claw
1
Connecting air hose
008396
Slip the air socket of the air hose onto the air fitting on
the nailer. Be sure that the air socket locks firmly into
position when installed onto the air fitting. A hose
coupling must be installed on or near the tool in such a
way that the pressure reservoir will discharge at the time
the air supply coupling is disconnected.
OPERATION
CAUTION:
Make sure all safety systems are in working order
•
before operation.
1.
To drive a nail, you may place the contact element
against the workpiece and pull the trigger, or
1
2
008397
008398
2.
Pull the trigger first and then place the contact
element against the workpiece.
No. 1 method is for intermittent nailing, when you
•
wish to drive a nail carefully and very accurately.
No. 2 method is for continuous nailing.
6
1. Air fitting
2. Air socket
1
2
1. Trigger
2. Contact arm