© Rotor Lips AG
Display: Supervisor Mode
In Automatic Mode
from Standard to Supervisor Mode. In Supervisor Mode the programmed mixing cycle is
played back step by step on the display (LED). This way the speeds which are stored in the
selected mixing cycle become visible. This display setting continues even after the machine is
restarted. Tapping in the same key combination again sets the display back to standard.
Tip: Film the display with a suitable device (e.g. Smartphone) to program the same mixing
cycles on other Rotary Memory Blenders.
Automatic switch off (Safety function against unintentional operation)
After 30 min. without a button being pressed, the machine stops and switches automatically to
the standby state.
Press button combination
Press the buttons 1+2+5+6 in
succession and hold them until
LEDs light up.
Press the buttons 1+3+4+6 in
succession and hold them until
LEDs light up.
Press the buttons 1+2+3+4 in
succession and hold them until
LEDs light up.13.5
9. SAFETY FEATURES
The safety control prevents the motor from being switched on when the Sound enclou-
sure is open, and stops it if the Sound enclousure is raised during operation.
When the Sound enclousure is closed, the cycle must be new started (reset function).
The „SAVE"-Button flashes red, if the sound enclousure is open.
10. MOTOR PROTECTION (OVERLOAD PROTECTION SWITCH )
When the machine is overloaded or overheated, it switches off
automatically.
When the machine stops automatically, immediately remove the complete con-
tainer from the motor unit, pull out the plug and swich off (0) the machine.
After about 60 seconds press the main switch 1/0 on the side
of motor base as usual.
Charge the machine less than before.
22
Instruction Manual
Rotor Memory Blender
the key combination «1+3+4+5», can be used to switch the display
2
Function ("AUTOMATIC" mode)
Overwrite protection of user programmes
- Save function is blocked. Programming no longer
possible.
- Blocking is lifted again with the same combination
Switch display to Supervisor Mode
- Shows the speeds of the respective mixing cycle.
Reset to manufacturer's settings
- All user programmed cycles are deleted.
CH-3661 Uetendorf