UNLCDHS Programming – LUX Control
Basic Parameters for EBDHS-B01-PRM
Parameter
Default
LUX Learn Level
LUX On Level
LUX Off Level
LUX On Time
LUX Off Time
UNLCDHS Programming – Configuration
Basic Parameters for EBDHS-B01-PRM
Parameter
Default
Factory Reset
Soft Reset
IR Enabled
UNLCDHS Programming – Device information
Under the device Info menu are items about the device that can be read back to the handset.
Note: Not all devices support any or all of the information below.
• Range: e.g Standalone
• Part number: e.g MWS6
• Variant: e.g DD, PRM output variants
• Version: Version of software of the device.
Range / Option
0
0 – 950
999
1 – 950,
999=disabled
999
1 – 950,
999=disabled
0
0 – 99 minutes
0
0 – 99 minutes
Range / Option
–
–
–
–
Yes
Yes / No
Use with the Readback function to get the LUX level the unit is currently
reading. Press Send to update the Light Level (MI) parameter with this value.
Sets the light level below which will turn on the output in conjunction with
movement control. The output will turn on without movement should the
Disable Detect parameter be set to YES.
999 disables both LUX ON and LUX OFF functions.
The LUX Off Level value must always be greater than the LUX On Level value.
Sets the light level above which will turn OFF the output in conjunction with
movement control.
999 disables both LUX ON and LUX OFF functions.
The LUX Off Level value must always be greater than the LUX On Level value.
When the ambient light falls below LUX ON Level, the time to wait before
switching on the lights. If at any time during the timed delay the LUX change
reverses then the process is cancelled. Minimum time of around 15 seconds
is set for a value of 0.
If you try to turn lights on using a switch or handset, the lights will go on
regardless of ambient light level. However, if there is sufficient ambient light,
they will turn off again after LUX Off Time.
When the ambient light rises above LUX OFF Level, the time to wait before
switching off the lights. If at any time during the timed delay the LUX change
reverses then the process is cancelled. Minimum time of around 15 seconds
is set for a value of 0.
Clears any programmed settings and returns the device to its default set-up.
Reboots the device, but retains all current settings. Must leave value at zero.
Set to No to prevent the device from receiving commands from the handset.
The device's LED will flash several times if you try to send a command when in
this state. Set to Yes to re enable programming.
Description
Description
7