Adjusting The Domestic Hot Water Temperature; Safety Stop; Reset Function - Beretta MYNUTE X 25 C Instrucciones De Instalacion Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SUMMER MODE
ƒ Set the boiler to the SUMMER status by pressing key 1 until the domestic hot water
icon is displayed.
In this status the boiler activates the traditional function of just domestic hot water, the
interface normally displays the delivery temperature. In the event of a domestic hot water
pick up, the display shows the temperature of the domestic hot water.
Domestic hot water REQUEST, the tap icon blinks:
OFF
ƒ Set the boiler to the OFF status by pressing key 1 until the central segments are
displayed.
4.7
Adjusting the heating water temperature without an outdoor
temperature sensor connected
If there is no outdoor temperature sensor the boiler operates at a fixed point, the HEATING
setpoint in this case can be set on the main page of the screen. Pressing the key C or D
displays the current heating setpoint; the value blinks with a frequency of 0.5 sec ON, 0.5
sec OFF and the icons
and
+
The successive pressing of the key C or D allows you to set the value of the heating setpoint
within the preset range:
[40°C - 80.5°C] for high temperature systems
[20°C - 45 °C] for low temperature systems
with steps of 0.5°C.
The level bars beside the heating icon show the setpoint value set with respect to the
operating range:
- four bars on = max setpoint
- one bar on = min setpoint
Keeping one of the two keys C or D pressed for longer, the meter increases the speed of
advancement modifying the set value. If no key is pressed for 5sec, the value set is taken
as the new heating setpoint and the display returns to the main page.
DAY
come on.
C
+
D
RESET
MENU
4.8
Adjusting the heating water temperature with an outdoor
temperature sensor connected
If an outdoor temperature sensor is installed and thermoregulation is enabled (parameter
P4.18 = 1), the delivery temperature is automatically selected by the system, which quickly
adjusts the ambient temperature according to the variations in the outdoor temperature. If
you want to change the temperature, raising it or lowering it with respect to the temperature
automatically calculated by the electronic board, it is possible to change the HEATING setpoint
as follows: press the keys C or D and select the desired level of comfort within the range (-5 -
+5) (see paragraph "4.4 Setting the thermoregulation").
Note: if an outdoor temperature sensor is connected it is in any event possible to have the
boiler operate at a fixed point by setting the parameter P4.18 = 0 (menu P4).
4.9

Adjusting the domestic hot water temperature

On the main screen, pressing the key A rather than B displays the current domestic hot
water setpoint, the value blinks with a frequency of 0.5 sec ON, 0.5 sec OFF and the icons
and
come on.
A
+
B
The successive pressing of the keys A or B allows you to set the value of the domestic hot
water setpoint raising or lowering the value within the preset range in steps of 0.5°C.
The level bars beside the heating icon show the setpoint value set with respect to the
operating range:
- four bars on = max setpoint
- one bar on = min setpoint
4.10

Safety stop

If there are ignition faults or boiler operation malfunctions, carry out a "SAFETY STOP". On
the display, in addition to the fault code, the icon
frequency of 0.5sec ON and 0.5sec OFF.
The backlight blinks for 1min after which it switches off, while the icon
On the 4 digits a message scrolls containing the error code and its description.
4.11

Reset function

The RESET icon comes on when there is an alarm that requires a manual reset by the user
(for example flame lockout). To reset press key 2 RESET.
If the release attempts do not restart the boiler, contact your local Technical Assistance
Centre.
+
RESET
MENU
is also displayed, which blinks with a
continues blinking.
DAY
DAY
RESET
ENGLISH
17

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mynute x 30 cMynute x 35 cMynute x 40 c

Tabla de contenido