MYNUTE X
3.20
Control panel
A
+
B
1
Led
Light signal indicating the operating status of the boiler. Can be red or green
(see specific paragraph)
A
It is normally used to raise the domestic hot water temperature, when the
arrow
is highlighted it has the confirm function
B
It is normally used to lower the domestic hot water temperature, when the
arrow
is highlighted it has the back/cancel function
A+B
Access to the domestic hot water comfort functions (see paragraph "4.12
Domestic hot water comfort function")
C
It is normally used to raise the heating water temperature, when the arrow
is highlighted you can move inside the P1 menu
D
It is normally used to lower the heating water temperature, when the arrow
is highlighted you can move inside the P1 menu
A+C
Access to the menu for setting the clock (see paragraph "4.2 Programming
the boiler")
1
Used to change the operating status of the boiler (OFF, SUMMER and
WINTER)
2
Used to reset the alarm status or to interrupt the vent cycle
Used to access the INFO and P1 menus. When the icon
3
on the display, the key has the ENTER function and is used to confirm the
value set during the programming of a technical parameter
1+3
Lock and unlock keys
2+3
When the boiler is set to OFF it is used to start the combustion analysis
function (CO)
The remote control has the function of a machine interface, displaying the system settings and providing access to the parameters.
The display normally shows the temperature of the flow sensor unless there is a domestic hot water request in progress, then the domestic hot water probe temperature is displayed; if no
key is touched within 10 sec the current time is displayed (backlight unlit).
The configuration MENU is organised with a multi-level tree structure. An access level has been fixed for each sub-menu: USER level always available; TECHNICAL level password
protected.
Below is a summary of the SETTINGS MENU tree structure.
Some of the information might not be available depending on the access level, the status of the machine or the system configuration.
10
LED
+
RESET
MENU
2
3
Enter
Indicates the connection to a remote device (OT or RS485)
Indicates the connection to a WIFI device
Indicates the presence of an outdoor temperature sensor
C
Indicates the activation of special domestic hot water functions or the
presence of a system for managing the solar thermal array
Indicates the connection to a heat pump (not used on this model)
D
Icon that lights up when there is an alarm
It comes on when there is a fault together with the icon
flame and water alarms
Indicates the presence of a flame, in the event of a flame lockout the icon
looks like
It comes on when there are alarms that require a manual reset by the
Reset
operator
Enter
It comes on when there is an operation confirmation request
When the icon is active, it indicates that the "confirm" function of button A
is active
When the icon is active, it indicates that the "back/cancel" function of
button B is active
When the icon is active, it is possible to navigate the menu or raise the
value of the selected parameter
When the icon is active, it is possible to navigate the menu or lower the
value of the selected parameter
The icon comes on if central heating is active, it blinks if a heating request
is in progress
The icon comes on if domestic hot water is active, it blinks if a domestic
hot water request is in progress
They indicate the set point level set (1 notch minimum value, 4 notches
maximum value)
Indicates the days of the week
1 2 3 4 5 6 7
is shown
AUTO
NOT AVAILABLE ON THIS MODEL
ON
MAN ON
NOT AVAILABLE ON THIS MODEL
MAN OFF
NOT AVAILABLE ON THIS MODEL
, except for