To re-install the front panel ......... Daikin website (publicly accessible). 5.1.3 To remove the front grille ..........▪ The full set of latest technical data is available on the Daikin 5.1.4 To re-install the front grille .......... Business Portal (authentication required).
RH 80%, the thickness of the insulation materials should be at wall, then additional insulation is required (minimum 10 mm least 20 mm to prevent condensation on the surface of the thickness, polyethylene foam). insulation. (A)(F)TXP20~35M5V1B + FTXP20~35M5V1B9 Installation manual Daikin room air conditioner 3P519299-4Q – 2020.06...
To open the service cover 1 Remove 1 screw from the service cover. 2 Pull out the service cover horizontally away from the unit. Upper hook Symbol with 3 circles Installation manual (A)(F)TXP20~35M5V1B + FTXP20~35M5V1B9 Daikin room air conditioner 3P519299-4Q – 2020.06...
▪ Do NOT put the end of the hose in water. Wall embedded pipe Putty Wall hole cover 4 After completing wiring, refrigerant piping and drain piping, do NOT forget to seal the gap with putty. (A)(F)TXP20~35M5V1B + FTXP20~35M5V1B9 Installation manual Daikin room air conditioner 3P519299-4Q – 2020.06...
▪ Coat the flare inner surface with ether oil or ester oil when left side. connecting a flare nut. Tighten 3 or 4 turns by hand, before tightening firmly. Installation manual (A)(F)TXP20~35M5V1B + FTXP20~35M5V1B9 Daikin room air conditioner 3P519299-4Q – 2020.06...
7 Connect the earth wire to the corresponding terminal. manufacturer, its service agent or similarly qualified 8 Firmly fix the wires with the terminal screws. persons in order to avoid a hazard. (A)(F)TXP20~35M5V1B + FTXP20~35M5V1B9 Installation manual Daikin room air conditioner 3P519299-4Q – 2020.06...
3 Turn the power supply on. Result: The flap of the indoor unit will open and close to set the reference position. Installation manual (A)(F)TXP20~35M5V1B + FTXP20~35M5V1B9 Daikin room air conditioner 3P519299-4Q – 2020.06...
Result: The user interface will return to the previous screen. Commissioning NOTICE ALWAYS operate the unit with thermistors and/or pressure sensors/switches. If NOT, burning of the compressor might be the result. (A)(F)TXP20~35M5V1B + FTXP20~35M5V1B9 Installation manual Daikin room air conditioner 3P519299-4Q – 2020.06...
9 Technical data Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is available on the Daikin Business Portal (authentication required). Wiring diagram The wiring diagram is delivered with the unit, located inside of the outdoor unit (bottom side of the top plate).