®
Jandy
Pro Series JE Heat Pumps
spa Mode - (normal Heat)
To enable the spa mode, press spa . The associated left
green LED indicator will light and the unit will display
sEt:xxx° .
XXX
notE
represents the current temperature setting
on the control. The default setting for spa
temperature is 102°F (38°C).
You can change the temperature set point by pressing
the up or down button . Repeatedly press the up or
down button until you reach the desired temperature
set point. After 5 seconds of inactivity, the new set point
is stored in memory. When the water temperature falls
to 1 degree below the temperature setting
minute delay, the control will start the heat pump and
the associated right LED will light RED.
spa Mode - (optional Maintain Heat)
If connected to an AquaLink, the Maintain Heat mode
allows the heat pump to monitor the temperature of the
water 24 hours a day by turning the spa pump on and
sampling the water temperature.
This feature only works when connected to
notE
an AquaLink
.
To operate in spa mode with the Maintain Heat feature,
press spa , then press MEnu, press the down button
until Maintain spa HEat is displayed, press the
MEnu button. The associated left green LED indicator
will light and the unit will display sEt:xxx°. Change
the temperature set point by pressing the up or down
button until the desired set point is displayed. After
5 seconds of inactivity, the new set point is stored in
memory.
5.3
operating Features of Hybrid units
with optional Chiller
The chiller is an optional equipment. Not all
notE
units are provided with chiller
pool Mode - (normal Chill)
To enable the pool mode, press pool . The associated
left green LED indicator will light and the unit will
display sEt:xxx° .
XXX
notE
represents the current temperature setting
on the control. The default setting for pool
temperature is 80°F (26°C).
Press the MEnu button. P ress the up or down button
until you reach pool CHill , press the MEnu button.
notE pool CHill will not be displayed if the unit is
not provided with chiller.
You can change the temperature set point by pressing
the up or down button . Repeatedly press the up or
down button until you reach the desired temperature
|
Installation and Operation Manual
and
after a 5
.
ENGLISH
set point. After 5 seconds of inactivity, the new set point
is stored in memory. When the water temperature rises
to 1 degree above the temperature setting
minute delay, the control will start the heat pump and
the associated right LED will light GREEN
pool Mode - (optional Maintain Chill)
If connected to an AquaLink, the Maintain Chill option
mode allows the unit to monitor the temperature of the
water 24 hours a day by turning the pool pump on and
sampling the water temperature.
This feature only works when connected to
notE
an AquaLink
.
When the temperature of the water rises above the
desired temperature setting, the control will then turn on
the unit and the associated right green LED will light.
To operate in pool mode with the Maintain Chill feature,
press pool , then press MEnu , then press the down
button until Maintain pool CHill is displayed,
press the MEnu button. The associated left green LED
indicator will light and the unit will display sEt:xxx° .
Change the temperature set point by pressing the up
or down button until the desired set point is displayed.
After 5 seconds of inactivity, the new set point is stored
in memory.
spa Mode - (optional Maintain Chill)
If connected to an AquaLink, the Maintain Chill mode
allows the heat pump to monitor the temperature of the
water 24 hours a day by turning the spa pump on and
sampling the water temperature.
This feature only works when connected to
notE
an AquaLink
.
When the water temperature rises above the
programmed temperature set point, the control will start
the heat pump.
To operate in the spa mode with the Maintain Chill
feature, press spa , then press MEnu , press the down
button until Maintain spa CHill is displayed,
press the MEnu button. The associated left green LED
indicator will light and the unit will display sEt:xxx° .
Change the temperature set point by pressing the up
or down button until the desired set point is reached.
After 5 seconds of inactivity, the new set point is stored
in memory.
Page 19
and
after a 5
.