Motor Lead Installation
NOTE: The included motor in the Fhoton™ SolarPAK does come with a factory installed individual conductor lead. To replace or install a
new lead, please follow these steps:
1.
Remove the plastic bag from the lead connector and spread the lubricant evenly around the lead prong.
2. Align the orientation key on the lead connector with the slot in the motor end bell, and press the lead connector firmly into the
socket.
3. Start the jam nut into the connector threads, ensuring that the threads are properly engaged.
4. Using a 0.75 in. (19 mm) open ended wrench, tighten the jam nut until it is snug. Recommended torque 15-20 lb-ft (20-27 Nm).
DO NOT OVER-TORQUE.

Fault Codes and Troubleshooting

The Fhoton™ Drive will attempt to operate the pump to deliver water even under adverse conditions. To ensure years of reliable service,
it must also protect the system components from conditions that might result in equipment damage. When adverse conditions arise, the
controller will continue to deliver as much water as possible at a reduced output if necessary, and will shut down only in extreme cases.
Full operation will resume automatically whenever abnormal conditions subside.
Error conditions may suspend certain features, reduce output, or shut down operation of the system for varying amounts of time
depending on the nature and severity of the error. Problems that merely reduce features or performance generally restore full operation
when the trouble condition subsides without stopping the pump or flashing an error code. An error code is displayed by the flashing LED
light.
If the drive has stopped to indicate a fault code, the associated time-out delay will vary depending on the nature of the fault.
21