Three-Phase Motor Specifications
MOTOR MODEL
234904xxxxx 0.50 0.37
234902xxxxx 0.75 0.55
234504xxxxx
Maximum Motor Cable Length (in feet)
Drive Model
581011100984-SP050HP
581013000864-SP075HP
581014200864-SP150HP
Maximum Motor Cable Length (in meters)
Drive Model
581011100984-SP050HP
581013000864-SP075HP
581014200864-SP150HP
* Maximum cable length from the drive to the motor is 1000 ft (305 m). External filtering is required for motor cable lengths exceeding this
maximum distance or nuisance tripping might occur. Contact Franklin Electric for additional assistance with external filtering for distances larger
than 1000 ft (305 m).
20
RATING
HP
KW
VOLTS
HZ S.F.
48
60
100
60
1.5
1.1
200
60
Table 4: Motor Specification Data
Motor HP
0.5
0.75
1.5
Motor KW
0.38
0.55
1.1
Table 5: Wire Sizing Charts
FULL LOAD
MAXIMUM LOAD
AMPS
WATTS
AMPS
1.6
10.3
600
13.3
1.5
6.9
830
8.6
1.3
5.8
1460
6.8
AWG Copper Wire Size, (75 °C Insulation)
14
12
10
50
90
150
130
220
340
310
500
790
Square Millimeter Copper Wire Size, (75 °C Insulation)
1.5
2.5
4
20
30
50
20
40
70
70
120
190
LINE TO LINE
KVA
RESISTANCE
CODE
WATTS
OHMS
875
0.35 - 0.43
N
1185
1.1 – 1.4
M
1890
2.5 – 3.0
K
8
6
4
240
380
600
530
830
1000
6
10
16
90
140
110
190
300
290
305