10 Adjust the Faucet's Water Temperature
This valve is NOT factory preset. Upon installation, the temperature of this
valve must be checked and adjusted to ensure delivery of a safe water
temperature. Water in excess of 110°F (43°C) may cause scalding.
Loosen Cap Screw about 1/4" (4-6 turns)
A
and lift up cover (do not remove).
Using cover, turn cartridge gently until
B
desired water temperature is reached. Do
not turn past stops as this may damage
unit. Push cover down and tighten screw.