USE OF THE PSX2
9.
Turn the jumper cables power switch to the "ON" position. Crank the
engine. Do not crank for more than six seconds. Allow the PSX2 to
cool for at least 3 minutes between six second jumpstart cycles.
10. After successfully starting the engine, turn the jumper cables power
switch back to the "OFF" position.
11. Remove the black negative (-) clamp and return to its stored position.
12. Remove the red positive (+) clamp from the battery and return to its
stored position.

Using the integrated work light

To use the integrated work light, simply press the work light power button
located directly below the work light (see Figure 2 on page 7 for location L).

Using the compressor

The air compressor in the PSX2 is designed as a convenient portable inflation
device. After ten minutes of continuous use, turn off the compressor and allow it
to cool for ten minutes. Continue use, if necessary, following this ten minutes on
/ ten minutes off cycle (see Figure 2 on page 7 for location K).
WARNING
Inflating a tire or object using the compressor
1.
Secure the inflator nozzle to the valve stem using the thumb latch (see
Figure 1 on page 6 for location F).
2.
Switch on the compressor via the switch on the front of the PSX2
(see Figure 2 on page 7 for location K).
3.
Check the pressure gauge (see Figure 2 on page 7 for location J).
Once desired psi is reached, remove the valve connector by releasing
the thumb latch.
4.
Turn off compressor via the switch on the front of the PSX2 .

Inflating other objects

1.
Place the appropriate inflation accessory nozzle on the valve
connector and secure with the thumb latch (see Figure 1 on page 6 for
location C).
2.
Insert the accessory into the deflated object.
3.
Turn on compressor via the switch on the front of the PSX2. Once
desired psi is reached, remove the valve connector from the inflated
object. Release the inflation accessory by releasing the thumb latch
and gently pulling the accessory out of the valve connector.
4.
Turn off compressor via the switch on the front of the PSX2.
030211
Allowing the compressor to run in excess of 10 minutes can
result in permanent damage to the compressor, jump start
unit, property or personal injury. Make sure the compressor
ventilation slots on the front of the unit are free of debris and
air can circulate around the compressor motor while in use.