11.
IMPIANTO ELETTRICO
Installazione da eseguire dall'utilizzatore
11. ELECTRICAL INSTALLATION
Power installations must be made by the user
11. ELEKTROANLAGE
Netzanschluss nur durch Elektrofachkräfte
1
V
0
HZ
230
50/60
32A aM
FU
40A aM
50/60
FU
CAVO ALIMENTAZIONE 3P+TERRA x 4mmq VERSIONI 400V
CAVO ALIMENTAZIONE 3P+TERRA x 6mmq VERSIONI 230V
L1
L2
L3
PE
arancio 4mmq vers.400V
arancio 6mmq vers.230V
L1
L2
L3
1
13
15
9
11
5
0
IG
2
16
10
14
12
6
23
24
25
nero 4mmq vers.400V
nero 6mmq vers.230V
FU1
nero 1.5mmq
17
18
19
16
15
FU2
17
18
19
nero 2.5mmq
KM1
KM2
W1
U1
V1
U2
V2
M1
M2
3
3
MORSETTO
TR
TRASFORMATORE 100VA 0-230-400/0-24/0-18
STM1/2 TERMOSONDA MOTORE COLONNA 1/2
SCA
SCHEDA CONTROLLO ALLINEAMENTO
SA
SEGNALATORE ACUSTICO CARRELLI AD ALTEZZA PERICOLOSA
RC
ANTIDISTURBO BOBINA CONTATTORI
M1/2
MOTORE COLONNE1/2
KS
RELE' COMANDO SALITA
KM1/2
CONTATTORE COMANDO MOTORE 1/2
INTERRUTORE GENERALE CON INVERSIONE DI MARCIA E
IG
COMANDO
FUSIBILE PROTEZIONE SECONDARIO TR.18Vac 5x20F 2A 250V
FU4
RAPIDO
FUSIBILE PROTEZIONE SECONDARIO TR.24Vac 5x20F 4A 250V
FU3
RAPIDO
FUSIBILI PROTEZIONE PRIMARIO TR.
FU2
VERS.230V 5x20F 1A 250V (RAPIDO)
VERS.400V 10.3x38 1A 500V gl (RAPIDO)
TERNA FUSIBILI PROTEZIONE LINEA MOTORI
FU1
230V 10.3x38 32A 400V Am (2x2.6KW) 14x51 40A 500V aM (2x3.5KW)
400V 10.3x38 20A 500V Am (2x2.6KW) 10.3x38 25A 500V aM (2x3.5KW)
FC2/4
FINECORSA DISCESA COLONNE 1/2
FCP1/2 INTERRUTTORE DI PROSSIMITA` COLONNE 1/2
RIFER. NOMENCLATURA
400
MOT.
20A aM
2x2.6KW
collegare a SCA
JP100 polo 1 e 2
25A aM
2x3.5KW
2
1
marrone 0,5mmq
400
0
2
1
16
18
FU4
230
rosso 1mmq
24
FU3
40
0
0
9
SCA JP701 polo 1
15
SCA JP701 polo 2
TR
22
giallo/verde 1mmq
22
KS
FC2
3
W2
9
rosso 0,5mmq
11. INSTALLATION ÈLECTRIQUE
L'installation doit être effectée par l'usager
11. ESQUEMA ELECTRICO
La instalación tiene que efectuarla el utilizador
n°7 IG mors.3
n°8 IG mors.1
7
8
1-2 18Vac
1
2
3
4
9 0V 24VAC
11 0VDC
JP400
12 24VDC
blu 0,5mmq
14
13
12
11
12
STM1
12
8
21
11
1
IG
STM2
2
20
11
FCP1
FCP2
KS
7
22
22
22
blu 0,5mmq
rosso 0,5mmq
FC4
KS
3
5
rosso 1mmq
5
rosso 0,5mmq
TERMINAL
TRANSFORMER 100VA 0-230-400/0-24/0-18
POST 1/2 MOTOR HEAT SENSOR
ALIGNMENT CONTROL BOARD
DANGEROUS HEIGHT SIREN
CONTACTOR COIL NOISE SUPPRESSOR
1/2 POST MOTOR
UP SWITCH RELAY
1/2 MOTOR CONTROL CONTACTOR
MAIN SWITCH WITH REVERSE AND CONTROL
TR SECONDARY SAFETY FUSE 18Vac 5x20F 2A 250V RAPID
TR SECONDARY SAFETY FUSE 24Vac 5x20F 4A 250V RAPID
TR PRIMARY SAFETY FUSES
VERS. 230V 5x20F 1A 250V (RAPID)
VERS. 400V 10.3x38 1A 500V gl (RAPID)
MOTOR LINE SAFETY FUSE TRIAD
230V 10.3x38 32A 400V Am (2x2.6KW) 14x51 40A 500V aM (2x3.5KW)
400V 10.3x38 20A 500V Am (2x2.6KW) 10.3x38 25A 500V aM (2x3.5KW)
1/2 POST DOWN LIMIT SWITCH
1/2 POST PROXIMITY SWITCH
NOMENCLATURE
0472-M004-7
ponticello su 1e2 per confugurazione
output su mors.10 di JP100 in DC
ponticello su 1 e 2 per
confugurazione output su
mors.10 di JP100 in DC
SCA
3
1 2
JP701
JP100
14 13 12 11 10 9 8 7 6 5 4 3 2 1
14
12
10
8
6
4
13
11
9
7
5
3
14
13
12
11
12
+
10
-
10
SA
9
8
3
7
4
7
7
5
6
3
8
7
IG
4
20
6
4
RC
KM2
KM1
9
9
9
9
5
11
2
22 morsetto 22
1
40 FU3 di TR
2
1
1
2
1
2
RC
9
3
63