BATTERY TESTING
RANGE
Battery voltage range: 1. 5 V ~ 12 V
Overload protection: 400 mA / 250 V Fuse
DIODES AND CONTINUITY TESTING
RANGE
Battery voltage range: 1. 5 V ~ 12 V
Overload protection: 250 V DC or AC rms
SPECIFICATIONS
Input: 9 V - - - (square battery)
DC voltage (V): 400 mV / 4 V / 40 V / 400 V ±(0.5%+2d) / 1 000 V ±(0.8%+2d)
AC voltage (V) True-RMS: 4 V / 40 V / 400 V ±(0.8%+3d) / 750 V ±(1.2%+3d)
DC current (A): 400 uA / 4 000 uA / 40 mA / 400 mA ±(1.2%+2d)
DC current (A): 4 A / 20 A ±(2%+3d)
AC current (A): 400 uA / 4 000 uA / 40 mA / 400 mA ±(1.5%+3d)
AC current (A): 4 A / 20 A ±(2.5%+5d)
Resistance (Ω): 400 ±(1%+3d) / 4 K / 40 K / 400 K / 4 M ±(1%+2d) / 40 M ±(1.5%+3d)
Capacitance: 51.2 nF ±(3%+10d) / 512 nF / 5.12 uF / 51.2 uF ±(2.5%+5d) / 100 uF ±(5%+10d)
Frequency (Hz): 5.12 Hz / 51.2 Hz / 512 Hz / 5.12 kHz / 512 kHz / 5.12 MHz ±(0.1%+5d)
Temperature: -20 to 150°C ±(3°C+1d) / 150 to 1 000 °C ±(3%+2d)
Operating temperature: 0 - 40 °C
Storing temperature: -20 to 60°C
Consumption: 0.1 mW/h
Stand by power consumption: not applicable
15
ACCURACY
±(5. 0 % of reading + 5 digits)
DESCRIPTION
Approximate diode voltage reading
A buzz will sound if resistance
is less than 100 Ω
TEST CONDITION
Charging current: Approx. 25 mA
TEST CONDITION
Direct current approx. 0. 4 mA
Inverted voltage approx. 1. 5 V
Open circuit voltage approx. 0.5 V