Tabla EMC
Emissions test
RF emissions CISPR 11
RF emissions CISPR11
Harmonic emissions lEC
61000-3-2
Voltage fluctuations / flicker
emissions lEC 61000-3-3
The device is intended for use in the electromagnetic environment specified below. The customer or
the user should assure that it is used in such an environment.
Immunity test
Electrostatic
discharge (ESD) lEC
61000-4-2
Electrical fast
transient/burst IEC
61000-4-4
Surge IEC 61000-4-5
Voltage dips, short
interruptions and
voltage variations on
power supply input
lines IEC 61000-4-11
Power frequency
(50/60Hz) magnetic
field IEC 61000-4-8
IACER S r
Electromagnetic emissions
Compliance
Group 1
Class B
Not applicable
Not applicable
Electromagnetic immunity
IEC 60601-1-2 test
level
±6 kV contact
±8 kV air
Not applicable
Not applicable
Not applicable
3 A/m
52 de 56
Electromagnetic environment
- guidance
The device uses RF energy only
for its internal function.
Therefore, its RF emissions are
very low and are not likely to
cause any interference in nearby
electronic equipment.
The device is suitable for use in
all establishments other than
domestic and those directly
connected to the public low-
voltage power supply network
that supplies buildings used for
domestic purposes.
Not applicable
Not applicable
Compliance level
±6 kV contact
±8 kV air
Not applicable
Not applicable
Not applicable
3 A/m
Electromagnetic
environment -
guidance
Floors should be wood,
concrete or ceramic tile.
If floors are covered
with synthetic material,
the relative humidity
should be at least 30 %.
Not applicable
Not applicable
Not applicable
Power frequency
magnetic fields should
be at levels
characteristic of a
typical location in a
PG229 Rev 00 17 06 16