Remote control code programming of the 2nd AUX channel:
• By the key SELECT, position yourself on the blinking LED L2 "CODE TX";
• Press key SET 3 times to memorize the 2nd auxiliary channel and the led will modify its blinking (1 1 1 0 1 1 1 0);
• Send the selected code with the remote control;
• The LED L2 will remain steady on for a second to indicate that programming has been completed.
• The extra time of 10 sec. to store a new AUX channel is then preview as for the PP channel.
Important note: If a code has already been entered or all 120 codes have been memorized, by repeating the programming operation, all
the programming LEDs will start to flash, indicating that no further storing is possible.
Deletion of remote control codes:
• By the key SELECT, position yourself on the blinking LED L2 "CODE TX";
• Activate the blinking of the code to be deleted (P.P., PED. or AUX, indicated by the respective blinking);
• Press and hold down key SET for more than 5 sec.;
• The LED switches off for 2 sec. and the procedure is completed;
• If the CODE, PEDESTRIANS, or AUX codes are deleted, the LED will remain off.
Important note: If both channels codes are deleted, the LED will remain off, by the contrary if only PEDESTRIAN codes remain stored, the
LED blinking mode will change (1 1 1 1 0 1 1 1 1 0).
Rule of the first saved Remote control:
When programming remotes the following rule is applied:
if the first remote to be saved is a rolling code type, the receiver will subsequently accept only rolling code remotes (thus providing
enhanced anti-intrusion security); if the first remote to be saved is a fixed code type, the receiver will subsequently accept both fixed code
remotes and rolling code remotes, although only the fixed part of the latter will be controlled (thus effectively relinquishing the security of
the rolling code system).
LED L3
8.1.3 -
- CONDO: "Condominium" logic:
The enabling of the Condominium function means that during the opening movement or during the pause time the control unit will not
respond to commands sent by Pushbuttons or remotes.
In contrast, during the closing movement a command sent by the Pushbuttons or the remotes will reverse the direction of movement. This
operating mode is invaluable when the automation includes a loop detector.
In the default configuration the control unit is set with the Condominium function disabled; if the Condominium function is required, proceed
as follows:
• By the key SELECT, position yourself on the blinking LED no.3;
• Press the SET key;
• LED L4 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
LED L4
8.1.4 -
- MOTOR TIME: Programming of the motors stroke (max 4 min.)
It is necessary to program the working time of the motors
To set a new stroke, programming must be carried out with leaves in closed position as follows:
• By the key SELECT, position yourself on the blinking LED no.4;
• Press the SET key; · Motor no.1 starts the opening phase;
• At the desired initial deceleration point, press the SET key again, LED L4 will start to flash more slowly and Motor 1 will decelerate;
• When the desired position is reached, press the SET button to end the Opening cycle;
• LED L4 will now resume flashing normally and Motor 2 will begin Opening;
• Repeat the work time programming procedure for Motor 2;
• Once programming of the motor Opening times has been completed, Motor 2 restarts Closing immediately: repeat the above
procedures for the Closing phase of Motor 2 and subsequently Motor 1.
If you wish to exclude the slowing down (strongly advised against), when opening, wait until you reach the fully open position and proceed
as follows:
• In the case of motors with encoders and / or electric limit switches, press the SET key once and the reclosing phase will start;
• In the case of motors without an encoder and / or electrical limit switches, press the SET key twice and the closing phase will
begin.
Important notes:
- If you do not require the control unit to perform the deceleration, during programming, when the open-close cycle has been
completed press the SET key twice consecutively rather than just once.
- If the control unit is used in the 1 Motor configuration (dip 1 of SW1 OFF), the programming of the working time of the Motor 2 is
not performed
- During programming, instead of the SET key on the control unit you can use the button on the remote already stored.
LED L5
8.1.5
- PAUSE TIME Automatic closing time programming:
The control unit is factory set with automatic closing disabled.
If you wish to enable automatic closing proceed as follows:
• By the key SELECT, position yourself on the blinking LED no.5;