EXTENDED MENU 1
8.2
The control unit is factory set to allow direct selection exclusively of the main menu functions. If you wish to enable the functions described
in Extended Menu 1, proceed as follows:
• Select blinking LEV LED and press SET once;
• Press SET once;
• The LED will start blinking (alternate flashing of LEV LED
In this way you have access to the setting of the following functions:
L1
HOLD-TO-RUN
"PEDESTRIAN BUTTON / SINGLE DOOR
L2
PP/OPEN
PPED/CLOSE"
L3
PEDESTRIAN BUTTON / DS3
L4
PHOTOTEST
L5
DS2 STOP IN CLOSE
L6
DS1 PARTIAL INVERSION
L7
BLOCK / 8K2
LEV
MENÙ
There will be 30 seconds to select the functions of the Extended Menu 1 using the SELECT and SET keys; once an additional 30 seconds
have elapsed the control unit reverts to the main menu.
LED L1
8.2.1
- HOLD-TO-RUN:
The control unit allows you to configure the "Dead Man Switch" function. In this way, using the radio controls and the buttons to send a
command, the following operation will be obtained: it will be necessary to keep the desired command all the time activated (button pressed
constantly) to obtain the movement of the gate. When you release the command, the gate will stop immediately. If this mode of operation
is desired, proceed as follows.
The control unit allows setting the "Deadman" operation. To enable this operation mode, proceed as follows:
• Make sure you have enabled the extended Menu 1 (as shown by the alternate flashing 1 0 1 0 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L1;
• Press the SET key;
• LED L1 becomes steady on and programming will be completed.
In this way, using both the remote controls and the shutter activation Buttons, the following operation will be obtained: it is necessary to
keep the desired command constantly activated (button pressed constantly) to obtain the movement of the door of the shutter. The release
of the control will cause the stroke to stop immediately.
Repeat the procedure if you wish to restore the previous configuration.
LED L2
8.2.2
- SINGLE LEAF OR PP. BUTTON = OPEN, PED. BUTTON = CLOSE:
The control unit allows a N.O. Pushbutton to be connected (CN2 input no. 10) to activate the gate in Pedestrian Opening mode.
It is however possible to use this input to connect a N.O. pushbutton operating in a different manner.
If you wish to enable the "Single Leaf" function, proceed as follows:
• The LED will start blinking (alternate flashing 1 0 1 0 1 0 of LEV LED);
• Select blinking LEV LED and press SET once;
• Press the SET key;
• By the key SELECT, position yourself on the blinking LED L2;
In this mode the PPED button can be used to operate only Motor 1.
In contrast, if you wish to enable "OPEN-CLOSE" mode in order to use the Pedestrian Pushbutton to activate exclusively closing of the gate
and the P/P Pushbutton to (CN2 input no. 11) to activate exclusively opening of the gate, repeat the operation described above, pressing
the SELECT key twice (LED L2 will blink rapidly) instead of just once. Repeat the procedure if you wish to restore the initial configuration.
LED L3
8.2.3
- PEDESTRIAN PUSHBUTTON / DS3:
The control unit allows a N.O. Pushbutton to be connected (CN2 input no. 10) to activate the gate in Pedestrian Opening mode.
However, this input can be used to connect a DS3 photocell (N.C):
• Select blinking LEV LED and press SET once; The LED will start blinking (alternate flashing 1 0 1 0 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L3;
• Press the SET key;
• LED L3 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the initial configuration.
LED L4
8.2.4
- PHOTOTEST (Photocells test):
The control unit is factory set with the photocells test disabled.
Proceed as follows if you wish to enable the function:
);
ON
SINGLE LEAF
DS3
ON
ON
ON
ON
1 FLASH
COMUNELLO ®Copyright 2021 - All rights reserved
OFF
PEDESTRIAN BUTTON
PEDESTRIAN BUTTON
OFF
OFF
OFF
OFF
49