DIP SWITCH SW1
The SW1 Dip-Switches allow you to select the 1 or 2 motor
function and define which of the two motors starts first and
which second.
SW1
SW1
SW1
ON
ON
ON
1
2
1
2
1
2
1
NOT
2
MOTOR
2
MOTOR
MOTOR
CONSID.
MOTORS
2 DELAY
MOTORS
1 DELAY
DIP SWITCH SW2
The SW2 Dip-Switches allow to change the direction of stroke
of each motor without physically intervening on the electrical
connections in the terminal block.
SW2
SW2
SW2
SW2
ON
ON
ON
ON
1
2
1
2
1
2
1
INV
INV
INV
INV
INV
INV
INV
OFF
OFF
MOT 1
OFF
OFF
MOT 2
MOT 1
MOT 2
2 WIRES CONNECTION TABLE:
DESCRIPTION
1
Power supply
6A
Motor power supply
2
Flashing light
4A, 5A
TX photocell
4B, 5B
RX photocell
6
Key selector
6B
Limit switches
6C
Encoder
3
Antenna
Tab1
The table refers to the example of wiring shown in the ABACUS model manual for swing motors.
NOTE: If the cables are of a different length than those shown in the table, the section of the cables must be determined based on the
actual absorption of the connected devices.
The requirements are reported in the EN 50575: 2014 standard:
With the publication of the standard EN 50575, in the list of harmonized standards for Regulation CPR 305/2011, Com. 2016 / C 209/03,
also electric cables, already subject to CE marking for the Low Voltage Directive 2014/35 / EU, must be CE marked also under the CPR
Regulation.
TRIMMER SENS: It regulates the SENSITIVITY of motors
TRIMMER FORCE: It regulates the FORCE of motors
2
INV
TRIMMER SLOWING: It regulates the slowdown speed of motors
CABLE
LENGTH from 1m to 20m
2 x 1,5 mm
3 x 1,5 mm
2 x 0,5 mm
EN standard 50575, in
the list of harmonized
2 x 0,5 mm
rules for the Regulation
4 x 0,5 mm
CPR 305/2011, Com.
2016/C 209/03
3 x 0,5 mm
3 x 0,5 mm
3 x 0,5 mm
RG58
Turning with a screwdriver towards the + increases the sensitivity and
therefore the motor will block its stroke more quickly if an obstacle is
detected.
Turning with a screwdriver towards the + increases the motor
force.
Turning with a screwdriver toward the + modifies the motor stroke
speed during deceleration in 3 STEPS
Vel.Min.
Vel.Med.
Vel.Max.
LENGHT from 20m to 50m
2
2 x 2,5 mm
2
3 x 2,5 mm
2
2 x 1,0 mm
2
2 x 1,0 mm
2
4 x 1,0 mm
2
3 x 1,0 mm
2
3 x 1,0 mm
2
3 x 1,0 mm
Massimo 20m
COMUNELLO ®Copyright 2021 - All rights reserved
2
2
2
2
2
2
2
2
33

Publicidad

loading

Productos relacionados para Comunello Automation QUAD-230V-HP