This Quick Start Guide does not replace the Operating
Instructions of this product. For complete instructions and
safety handling information, see the Operating Instructions:
Touchscreen Unit:
DVD: Delivered with the product
Proceq Website: www.proceq.com Downloads
Scope of Delivery
Equotip 550 (35610001)
Equotip 550 Leeb D (35610002)
Equotip 550 Leeb G (35610003)
Equotip 550 Leeb U (35610006)
Equotip 550 Portable Rockwell (35610004)
Equotip 550 UCI (35610005)
A Carrying Case
B Equotip Touchscreen
C Battery complete
D Power Supply incl. cables
E USB Cable
F DVD with Software and Documentation
G Documentation
H Carrying Strap complete
I
Surface Roughness Comparator Plate
J Equotip Leeb Impact Device D
K Equotip Leeb Impact Device G
L Equotip Leeb Impact Device U
M Equotip Portable Rockwell Probe
N Equotip UCI Probe
O Equotip Leeb Impact Device Cable
P Equotip Leeb Impact Device U Cable
Q Equotip Portable Rockwell Probe Cable
R Equotip UCI Probe Cable
S Equotip Test Block
T Equotip Portable Rockwell Test Block
U Equotip UCI Test Block
V Equotip Leeb Impact Device Cleaning Brush
W Coupling Paste
Getting Started
1
Battery Installation
To install the battery, remove the
protection foil and lift the stand
as shown. Insert the battery and
fasten it in place with the screw.
Load Battery
The battery must first be charged 8 hours before using.
Connect through the power supply connection. A Quick
Charger (32701053) is available (full charging < 5.5 h).
Connect the Probe
1 2
Snap-in connectors
• • •
For Leeb Impact Devices
• • •
use the Snap-in connector 1.
• • •
For UCI Probe
• • •
use the Snap-in connectors
• • •
1 or 2.
• • • • • •
For the Portable Rockwell
• • • • • •
Probe use the USB Host
connector.
• • • • • •
• •
• • •
•
•
•
Start the Instrument
•
Press Power ON/OFF to power on.
•
• •
Software Upgrade
•
It is recommended to check for firmware upgrades before
•
using the instrument for the first time. (See Equotip Link).
•
• •
•
•
• •
• •
2
On start up, the main menu is displayed. All functions are
accessible directly via the Touchscreen.
Return to the previous menu by pressing the Back Button
or the return icon (arrow) at the top left of the Touchscreen.
Hardware Connections
USB Host
USB Device
Ethernet
Power Supply
USB Host:
Additionally connect a
mouse, keyboard or USB
stick.
USB Device:
Connect to PC.
Ethernet:
Connection to network.
Power Supply:
Connect the power supply
through this connection.
3
Install the Equotip Link software provided on the DVD.
Connect the instrument to a PC using the USB cable
provided. Make sure you are connected to the Internet.
Updates should be performed periodically to take advantage
of Proceq's continuous firmware development.
3
Main Menu
Measurement
Measurement screen.
Settings
Application settings; See Operating Instructions
for details.
Data
File manager; review of saved measurements
on the instrument.
Wizards
Predefined workflows to increase process
reliability and time efficiency.
Information
Contains comprehensive Operating Instructions
and important device information.
System
Define your interface language, date, time and
other system settings.
Power off
Switch off the device.
Equotip Link
Click on the PQ-Upgrade icon to check for
software updates.
© 2017 Proceq SA