SEA CORONA 60 Manual Del Usuario página 8

Ocultar thumbs Ver también para CORONA 60:
Tabla de contenido

Publicidad

Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
Opening
limit switch
slide application
Operator body
To adjust the closing of the door in a millimetric way after placing the limit switch slides act on the drawing curved rod releasing the bolts and
adjusting the running through the two holes (Fig. 20)
6. PROCESS OF CARD SELF-PROGRAMMING
After having correctly placed the limit switches (paragraph 5) and tested the right running of the door and the electric connections on the
inputs/outputs, make the following:
1. Power supply the control unit MINI GATE 24V
2. Position the door next to the stop in closing using the push buttons S2 and S3 (50cm ca.)
3. Bring Dip Switch 4 on ON position
4. Make sure that during the learning process the stop, photocell, safety edge, etc. orders are not set up.
5. Push button S1
6. The door will execute the closing manoeuvre until reaching the limit switch
7. At this point, an opening and a closing manoeuvre will be executed automatically
8. When the door will stop and will be completely closed, bring Dip switch 4 on OFF position again.
9. The automation is ready to work
Make the necessary regulations through the trimmers and the Dip Switches.
18
67410620
®
CORONA
Fig. 19a
Rev 09 - 03/2011
Closing
limit switch
slide application
Operator body
Fig. 19b
ENGLISH
Fig. 20

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Corona 110

Tabla de contenido