6
Troubleshooting
Problem
Expected number of test
rundowns is not achieved
with one charge of the bat-
tery.
No LCD display
Changing LCD display
Charger indicates battery
fault
7
Service
Keep contacts free from contaminations. This is the only way to ensure smooth functioning.
8
Maintenance
If repair is required, send the complete battery to our Sales & Service Center!
It may be repaired only by authorized technicians. Opening the battery will void the warranty.
2070b_1_5en_bedingt.fm, 24.06.2015
EN
Possible cause
Battery is not fully charged.
The warning threshold for undervolt-
age is not set to minimum value.
A high torque was required for the run-
downs, e.g. for coated screws or for
several revolutions.
Battery has too many charging cycles. After 800 charging cycles the capacity
Battery is in Deep Sleep Mode
Battery is defective
Battery temperature is > 118.4° C
Battery detecting short-circuit
Battery is defective
P2070BA/EN 2015-06
Troubleshooting
Measure
Use fully charged battery.
Set the undervoltage to 37,2 Volt
using the control on the tool
screen.
Using a high torque for a longer period
of time will reduce the number of run-
downs to be achieved with one battery
charge.
is reduced to approx. 60%.
Recharge battery with charger
Replace battery
Leave the battery to cool. Display
expires.
Remove short-circuit.
Push battery on to battery charger.
This will reset the error message.
Replace battery
6
23