2.4 Installation
Connection for MMA welding
The connection shown in the figure produces
reverse polarity welding. To obtain straight polar-
ity welding, reserve the connection.
- Connect (3) the earth clamp to the negative socket (-) (4) of
the power source.
- Connect (1) the electrode holder to thpositive socket (+) (2)
of the power source (WF).
Connection for deseaming ARC-AIR
COMPRESSED
AIR
COMPRESSED
AIR
- Connect (5) the earth clamp to the negative socket (-) (6) of
the power source.
- Connect (7) the ARC-AIR holder to the positive socket (+) (8)
of the power source.
- Connect separately the connector on the air (9) pipe to the air
supply.
Connection for TIG welding
- Connect (10) the earth clamp to the positive socket (+) (11)
ofthe power source.
- Connect the TIG torch coupling (12) to the torch socket (13)
ofthe power source.
- Connect the gas hose from the cylinder to the rear gas con-
nection.
- Connect the signal cable (14) of the torch to the appropriate
connector (15).
- Connect the gas hose (16) of the torch to the appropriate
union/connection (17).
Connection for MIG/MAG welding
- Connect the CAN-BUS signal cable for the control of external
devices (such as RC) to the appropriate connector (18).
- Insert the connector and rotate the ring nut clockwise until
the parts are properly secured.
- Connect the power cable (19) to the appropriate outlet (20).
Insert the plug and turn clockwise until all parts are secured.
- Connect the signal cable (21) to the appropriate connector (22).
Insert the connector and screw the ring nut clockwise until all
parts are secured.
- Connect the gas hose (23) to the pressure reducing valve of
the cylinder or to the gas supply connection (24).
- Connect the water pipe (blue colored
quick connector of the cooling unit.
- Connect the water pipe (red colored
connector of the cooling unit.
) to the outlet
) to the inlet quick
41